6
O
PERATION
P
R O C E S S O R S
/ C
O N T R O L L E R S
The SlingShot operates with any four-way processor or controller. A software file is available
for the XTA DP266 and BSS Omnidrive, Omnidrive Compact and Omnidrive Compact Plus.
The file can be downloaded from the service and support area of the Mach web site at
http://www.mach.dk. For other processors or controllers, please refer to the settings in the
specifications.
The SlingShot combination MS1262 / MS118 or M182T may be operated with the Mach MS3
three-way analog controller. For three-way operation with the MS3, the MS1262 must be
rewired for passive mode operation. See “Wiring” on page 8. Power handling in three-way
(passive) mode for the 6” and the 2” in combination is 275 watts and the load is 8 ohms.
B
R E A K
-
I N
P E R I O D
The SlingShot drive units are hand-made of exceptionally strong and durable materials that
must be broken in for a short period before they perform fully to specification. Each drive unit
requires approximately 10 hours of use, and subs require approximately 30 hours, to break in.
No precautions or special procedures are necessary during the break-in period.