ENG
Input interface
Dry contact signal or +12V level signal
or pulse signal with width of more than
100ms DC12V, driving current: > 10mA
Communication interface
RS485(standard)
Distance less than 1200metres
Transit speed
40 persons/min(open often),
25-30 persons/min(close often)
Time for opening or closing
2-3seconds
Starting time after power is on
3 seconds
Automatic reset time after fault
10 seconds
Working environment
Indoor, outdoor( with a tent over)
Temperature
-10°C ~ 50°C
Relative humidity
≤90% no condensation
Installation instruction
1.
Installation on the ground
First of all, earthwork (a concrete base foot of 200mm height for anti-humidity)
(Hereinafter called Safe island) should be built. Then, power cable of 220V3*1.5mm
and two 4*0.5mm control cable should be laid under the middle of the casework.
Fix the mechanism on the safe island by 4 bolts according to the installation dia-
gram. Connect it with power of 220V and control cable should be linked to con-
trol room.