![Mach Power AC-AFDSC-012 User Manual Download Page 7](http://html1.mh-extra.com/html/mach-power/ac-afdsc-012/ac-afdsc-012_user-manual_4377946007.webp)
7
ENG
16.
Delay Closing time
17.
Swing barrier Dire, Open-left, Open-right
18.
Break-in Operation, No close, Closed
19.
Motor brake, Close, Open
20.
Machine L-open set, UP+1 Down -1
21.
Other option
22.
Machine test
Main board Parameter
Brush motor flap barrier(swing barrier)main board parameter
Basic introduction
Input power
Voltage DC24V Current4.5A
Working temperature
-15°C ~ 60°C
Working humidity
≤80%
Main board consumption <2W
IP
IP52
Input terminal
introduction
Switch power supply
Voltage DC18V ~ 26V
Current 3A ~ 6.5A
IR sensor signal
Voltage DC2.5V ~ 24V
Current 5mA ~ 20mA
Limit sensor
Voltage DC2.5V ~ 24V
Current 5mA ~ 20mA
Open signal,
Fire signal
Dry contact signal or +12V le-
vel signal. driving curre 5mA ~
20mA
Battery
12V 1HA ~ 5HA
Serial port
485
Output terminal
introduction
Voice port
4Ω~8Ω 10W
Direction board port
DC12 5mA~20mA
Motor port
DC 24V <2A
Light port
No
Clutch port
No
Fire output port
No