Edit a "Channel value level status" channel type
ON when below level
The related "
" will be turned ON when the input channel value is less than the "
Level
value
", and OFF when the input channel value is greater than the "
Level value
" plus the "
Hysteresis
value
".
OFF when above level
The related "
" will be turned ON when the input channel value is greater than the
"
Level value
", and OFF when the input channel value is less than the "
Level value
" minus the "
Hysteresis
value
".
In the example above, the "Binary status output" will be turned ON, when the "Source channel named -
Depth" has a value of less than 1.0 metres and OFF when the "Source channel named - Depth" has a
value of greater than 1.1 metres.