214657
198
Revision A
Figure 5.68: Access Cover
8.
Install access cover (B) using two screws (A) coated
with medium-strength threadlocker (Loctite
®
243 or
equivalent). Torque screws to 8.5 Nm (75 lbf
∙
in).
NOTE:
If reusing hardware, apply a fresh coat of medium-
strength threadlocker.
5.6.2
Replacing Auger Finger Guides
If the hole in the finger guide has elongated to the maximum length of 24 mm (15/16 in.), replace the finger guide.
DANGER
To avoid bodily injury or death from unexpected startup of machine, always stop engine and remove key
from ignition before leaving operator
’
s seat for any reason.
1.
Raise the hold-down fully, and engage lift cylinder safety props.
2.
Shut down the combine, and remove the key from the ignition.
Figure 5.69: Access Cover
3.
Remove two screws (A) from the access cover (B)
closest to the finger guide being replaced, and remove
access cover.
4.
Remove auger finger (C). Refer to
.
Summary of Contents for PW8