214657
186
Revision A
Figure 5.39: Left Side of Header
10. Pull hoses through hole (B) in endsheet and through
hole (A) in frame.
Installing Hydraulic Motor Hoses
Figure 5.40: Left Side of Header
1.
Route the two longer hoses (A) and (B) through hole (C)
in endsheet and hole (D) in frame.
NOTE:
Angled fitting on hose (B) attaches to the pick-up rear
drive motor. Hose (A) with yellow cable ties has
identical fittings at both ends and attaches to the
forward drive motor fitting that has a matching yellow
cable tie.
Figure 5.41: Multicoupler on Rear of Header
2.
Route hoses (A) and (B) through grommet (C) in bottom
beam cover. Match colored cable ties and attach
hoses (A) and (B) to multicoupler. If colored cable ties
are missing, attach as follows:
a.
Attach longer hose (A) to forward port on forward
drive motor and to connector (E) on multicoupler.
b.
Attach shorter hose (B) to aft port on rear drive
motor and to connector (F) on multicoupler.
c.
Secure hoses with cinch strap (D).
Summary of Contents for PW8