262171
261
Revision A
1014968
A
B
Figure 5.141: Operator
’
s Console Draper Controls
4.
Set the draper speed with the console controls as follows:
a.
Press and quickly release DRAPER SPEED switch (A) to
increase the draper speed in 0.2 km/h (0.1 mph)
increments.
b.
Press and hold DRAPER SPEED switch (A) to increase
the draper speed in 2 km/h (1 mph) increments.
c.
Similarly decrease draper speed with switch (B).
Adjusting Draper Alarm Pressure
Adjusting the draper alarm allows the Operator to set an alert to inform them that the draper is operating above the
desired pressure. A lower setting will cause the alarm to be set off more often; a higher setting will allow the alarm to be
set off less frequently. This adjustment requires the header to be in operation.
ϭϬϰϮϬϱϵ
A
Figure 5.142: HarvestTouch
™
Display - Header
Run Screen
1.
Engage the header to display header run screen 1 or 2.
2.
To adjust the reel pressure alarm set point, press DRAPER
SETTINGS icon (A) to access the DRAPER ADJUST page.
ϭϬϰϮϬϲϬ
A
Figure 5.143: Draper Adjust Page
3.
Press set point arrows (A) to set the desired pressure point
that will trigger the alarm.
NOTE:
The factory setting is 200 bar (2900 psi). Adjusting past the
highest setting turns the alarm off.