4.6.3
Calibrating the Header Float Sensors
NOTE:
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
•
Use the left or right FLOAT buttons on the cab display module (CDM) to perform this procedure.
1021948
A
Figure 4.87: Float Pin
–
Right Side
IMPORTANT:
Ensure float pins (A) are installed in the working position.
1009099
CXXX
MXXX
WINDROWER SETUP?
NO/YES
A
B
Figure 4.88: CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (B) on cab display module
(CDM) to enter programming mode.
•
WINDROWER SETUP? is displayed on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? is displayed on
the upper line.
•
NO/YES is displayed on the lower line.
1009285
CXXX
MXXX
CALIBRATING FLOAT
PRESS FLOAT + TO START
C
B
A
Figure 4.89: Header Float Display
4.
Press right arrow (B) to select YES. Press SELECT (C).
•
TO CALIBRATE SELECT is displayed in upper line.
5.
Press left arrow (A) or right arrow (B) until HEADER FLOAT
is displayed on the lower line. Press SELECT (C).
•
CALIBRATING FLOAT is displayed on the upper line.
•