215676
111
Revision A
1009221
CXXX
MXXX
NO/YES
SET CONTROL LOCKS?
B
A
Figure 3.120: Control Locks
4.
Press SELECT (B) until SET CONTROL LOCKS? appears on the
upper line.
•
NO/YES will appear on the lower line.
5.
Press right arrow (A) to select YES. Press SELECT (B).
1009236
CXXX
MXXX
HEADER FLOAT
ENABLED/LOCKED
D
C
B
A
Figure 3.121: Header Float Control Lock
6.
Press SELECT (D) until HEADER FLOAT appears on the
upper line.
•
ENABLED/LOCKED will appear on the lower line.
7.
Press left arrow (B) to enable the HEADER FLOAT control
switch, or press right arrow (C) to lock the HEADER FLOAT
control switch.
8.
Press PROGRAM (A) to exit programming mode or press
SELECT (D) to proceed to the next WINDROWER SETUP
option.
Activating Reel Fore-Aft Control Lockout
Activating the header reel fore-aft control lockout in the windrower
’
s cab display module (CDM) prevents unauthorized
Operators from changing the reel fore-aft setting of the attached header.
NOTE:
•
This procedure applies to windrowers with attached draper headers only.
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header. For more information, refer to
.