5.11 Every 1000 Hours
Complete the following maintenance tasks every 1000 hours of operation.
• Change fuel tank vent
fi
lter. Refer to
5.11.1 Removing and Installing the Fuel Tank Vent Filter, page 293
.
• Clean DEF supply module
fi
lter. Refer to
5.11.2 DEF Supply Module Filter, page 295
.
• Change wheel drive lubricant. Refer to
5.5.7 Changing Wheel Drive Lubricant, page 251
5.11.1 Removing and Installing the Fuel Tank Vent Filter
The fuel tank is vented by a hose and
fi
lter in the platform rail. Change the
fi
lter every 1000 hours or annually,
whichever occurs
fi
rst.
Change the
fi
lter as follows:
DANGER
To avoid bodily injury or death from unexpected startup of the machine, always stop the engine and remove
the key from the ignition before leaving the operator’s seat for any reason.
WARNING
To avoid personal injury or death from explosion or
fi
re, do NOT smoke or allow
fl
ame or sparks near
windrower when servicing.
1. Shut down the engine and remove the key.
2. Remove two bolts (A) and plate (B) on the right service
platform.
Figure 5.91: Right-Hand Service Platform
214053