214685
45
Revision A
4.2.6
Converting from Ultra Narrow or Narrow Configuration to Wide
Configuration
One kit of MD #287031
4
is required to convert to this configuration. Two flighting plugs (MD #213084), two M6 hex
head bolts (MD #252703), and two M6 tee nuts (MD #197263) are recommended to close the flighting mounting
locations. These parts can be ordered from a MacDon Dealer.
Figure 4.31: Auger Configurations (Rear View)
1 - Narrow Configuration
2 - Ultra Narrow Configuration
3 - Wide Configuration
The Narrow, Ultra Narrow, and Wide auger configurations
are shown at right. When converting from Narrow or
Ultra Narrow configuration to Wide configuration, you will
need to replace the existing flightings (A).
NOTE:
Some parts have been removed from the illustrations for
clarity.
1.
If necessary to improve access and ease installation, remove float module from combine. For instructions, refer
to the header operator
’
s manual or technical manual.
Figure 4.32: Narrow Configuration (Right Side)
2.
Remove bolts (A) and access cover (B) from the right
side of the auger. Retain for later reassembly.
3.
Remove hardware (C) and bolt-on flighting (D) from the
right side of the auger. Discard flighting, but retain
hardware to attach the new flighting.
4.
Remove flighting slot plug, bolt, and tee nut (E). Retain
for later reinstallation.
NOTE:
Only two flighting slot plugs (E) should be removed
—
one from each outboard side of the auger.
5.
Repeat Step
and Step
for the
remaining bolt-on flighting(s).
4.
MD #287031 contains wear-resistant flightings, and is available only through MacDon Parts.
Summary of Contents for FlexDraper FD1 Series
Page 2: ...FD1 Series FlexDraper Header Published June 2018...
Page 12: ......
Page 42: ......
Page 45: ...214685 33 Revision A Figure 4 6 Filler Cap 10 Install filler cap A SETTING UP FLOAT MODULE...
Page 72: ......
Page 116: ......
Page 166: ......
Page 336: ......
Page 350: ......
Page 353: ......