Displayed on LCD (A) as XX in. or XXX cm.
Figure 3.198: Combine Heads up Display
Alarm conditions:
If an error message is received from the fuse panel, an audible alarm sounds. The LCD on the electronic instrument
panel (EIP) indicates the header system in error as HDR CTRL followed by HGT ERR for height, and HDR CTRL
followed by TILT ERR for tilt. The header height LED
fl
ashes yellow two times every second.
The alarm also is noted by the buzzer sounding
fi
ve times every ten seconds.
When an alarm condition occurs, a green LED
fl
ashes on and off (green, yellow, or red depending on the input). In
addition, a message is displayed on the LCD to identify the nature of the alarm. For example, HYD TEMP, OPEN,
SHRT will be
fl
ashed alternately.