214325
241
Revision A
Figure 5.219: Joystick Buttons
NOTE:
Reel fore-aft position can also be set using joystick.
9.
Press and hold button (C) or button (D) for 3 seconds to
store setting into CEBIS (CLAAS Electronic on-Board
Information System). An alarm will sound when new
setting has been stored.
NOTE:
Whenever button (C) or button (D) is pressed for 3
seconds, current positions for reel speed and cutting
height are stored.
5.1.13
CLAAS 700 Series Combines
This section applies to CLAAS 700 Series combines. Refer to
5.1.12 CLAAS 500 Series Combines, page 229
for
CLAAS 500 Series.
Auto Header Height Sensor Voltage Requirements
The auto header height sensor output must be within a specific voltage range for the feature to work properly.
Combine
Lower Voltage Limit
(+/- 0.2)
Upper Voltage Limit
(+/- 0.2)
Minimum Range
Difference
CLAAS 500/600/700
Series
0.7 V
4.3 V
2.5 V
Check sensor
’
s output voltage range at float indicator according to the instructions that follow.
Checking Sensor
’
s Output Voltage Range
The auto header height sensor output must be within a specific range for feature to work properly. To check
sensor
’
s output voltage range, follow these steps:
1.
Position header 150 mm (6 in.) above ground, and rest it on safety props. Unlock adapter float.
NOTE:
If header is not on down stops during next two steps, voltage may go out of range during operation causing a
malfunction of auto header height control (AHHC) system.