OptoLink A-CCP, A-FCR, BCR or CCR receptacle
■
If the optical lenses are dirty, clean with a dry cotton swab and
isopropyl alcohol
■
If the optical lenses are greasy, clean with an isopropyl alcohol
soaked cotton swab followed by a dry cotton swab
■
Repeat the cleaning process if necessary
■
O-rings must be checked before mating/mounting and will require
replacing if they show signs of damage
■
Always grease O-rings with Molykote 111
Note: Always install dust caps when connectors are unmated
Maintenance
Use of Loctite for mounting FCR and BCR
■
For locking metallic connectors, the use of Loctite 243 is
recommended
OptoLink Penetrator harnesses
■
O-rings must be checked before mounting and will require
replacing if they show signs of damage
■
Always grease O-rings with Molykote 111