background image

OptoLink A-CCP, A-FCR, BCR or CCR receptacle

 

 

If the optical lenses are dirty, clean with a dry cotton swab and  

 

isopropyl alcohol 

 

If the optical lenses are greasy, clean with an isopropyl alcohol  

 

soaked cotton swab followed by a dry cotton swab 

 

Repeat the cleaning process if necessary 

 

O-rings must be checked before mating/mounting and will require  

 

replacing if they show signs of damage 

 

Always grease O-rings with Molykote 111

Note: Always install dust caps when connectors are unmated

Maintenance

Use of Loctite for mounting FCR and BCR

 

 

For locking metallic connectors, the use of Loctite 243 is  

 

 recommended

OptoLink Penetrator harnesses

 

 

O-rings must be checked before mounting and will require    

 

replacing if they show signs of damage 

 

Always grease O-rings with Molykote 111