background image

 

 

 

 

 

 

 

 

Made in Italy 

 

Cod. /620080020 Dis.7174 Rev.03 05-2015

 

 

Manual utilizare Presostat electronic Pressystem

Summary of Contents for PresSystem

Page 1: ...Made in Italy Cod 620080020 Dis 7174 Rev 03 05 2015 Manual utilizare Presostat electronic Pressystem...

Page 2: ...ce Electrical connection 17 4 Prima utilizare FIRST STARTUP 21 4 1 Functionarea Automata Automatic Operation 23 4 2 Functionarea mod presostat Pressure switch Operation 24 4 3 Intrerupere curent Break...

Page 3: ...responsible for any damages caused by a not correct installation or maintenance The use of non original spare parts tempering or improper use make the product warranty null AVERTIZARE PresSystem treb...

Page 4: ...lizat specializat conform normelor in vigoare PresSystem trebuie protejat cu un comutator siguranta termic a PresSystem trebuie conectat la o instalatie cu impamantare functionala si eficienta and run...

Page 5: ...chimb In cazul in care aveti nevoie de instructiuni sau sunteti intr o situatie ce nu este acoperita de acest manual va rugam contactati departamentul de suport tehnic This manual intends to provide e...

Page 6: ...em este un dispozitiv Auto programabil sau programabil de catre utilizator Se adapteaza oricarei pompe sau oricarei inaltimi de pompare The PresSystem is a new electronic product by MAC3 designed to c...

Page 7: ...tern ce permite reglarea presiunii de pornire Fara supapa de sens pentru a preveni pierderea de debit Protectie Lipsa Apa cu resetari automate prin sesizarea variatiei de presiune PresSystem is mounte...

Page 8: ...au lipsei unui vas de expansiune PresSystem poate functiona ca un presostat mecanic traditional restarts through the control of the pressure variation Protection against dry running with automatic res...

Page 9: ...temperii Instalarea PresSystem trebuie facuta intr un sistem ce nu este expus loviturilor de berbec ex cu vas de expansiune Vasul de expansiune trebuie intretinut corespunzator Ambient temperature bet...

Page 10: ...manual utilizare presostat electronic pressystem 10...

Page 11: ...manual utilizare presostat electronic pressystem 11 2 4 C a r a c t e r i s t i c i t e h n i c e T e c h n i c a l f e a t u r e s...

Page 12: ...1 C 40 C Liquid temperature 1 C 40 C Teava AISI 304 Pipe AISI 304 Filete 1 exterior potrivit si pentru tevi de 1 Input Output 1 male suitable for pipes of 1 see Pressure drop Presiune de lucru 1 5 8 b...

Page 13: ...manual utilizare presostat electronic pressystem 13 3 INSTALARE INSTALLATION 3 1 L e g a t u r i l e h i d r a u l i c e H y d r a u l i c c o n n e c t...

Page 14: ...min vas de expansiune de 10lt Valoarea presiunii de pre incarcare cu aer a vasului de expansiune trebuie sa fie aprox 80 din presiunea instalatiei Pentru intretinerea usoara a instalatiei hidraulice...

Page 15: ...mandata instalarea unui robinet in apropierea PresSystem in linie cu vasul de expansiune Vasul de expansiune robinetul sau orice alt consumator nu trebuie montat inaintea PresSystem It is recommended...

Page 16: ...presostat electronic pressystem 16 Figura 1 Di seguito schema d esempio di un tipico impianto con pompa di superficie Example of a typical system with surface pump X NO Supapa de sens obligatorie Chec...

Page 17: ...manual utilizare presostat electronic pressystem 17 3 2 L e g a t u r i l e e l e c t r i c e E l e c t r i c a l c o n n e c t i...

Page 18: ...ough a circuit breaker sized according to the pump rating Connect the output cable phase neutral ground to the pump Connect the pump with a cable section adapted according to its length Example Sectio...

Page 19: ...pmple de legaturi electrice Some examples of connection Conexiune standard pentru vers 230Vac Standard connection 230Vac version Conexiune cu flotor electric pentru vers 230Vac Connection with float s...

Page 20: ...essystem 20 Conexiune standard pentru vers 117Vac Standard connection 117Vac version Conexiune cu flotor electric pentru vers 117Vac Connection with float switch L N GND 117 V 60hz L N GND U V M 1 L N...

Page 21: ...manual utilizare presostat electronic pressystem 21 117Vac version L N GND 117 V 60hz L N GND U V M 1 J5...

Page 22: ...a in eroare After successful installation of hydraulic and electrical connections it s possible to turn on the PresSystem It s important that the first power on of the device is made with all taps clo...

Page 23: ...loarea si butonul pentru a o scadea 5 Apasati butonul EDIT pentru a salva datele introduse sau apasati butonul ON OFF pentru a iesi fara salvare Dupa setarea amperasjului LEDul PRESSURE lumineaza si p...

Page 24: ...LED DRY RUNNING pragul amperajului cos pentru protectia Lipsa Apa LED COS the pressure threshold for the dry running LED DRY RUNNING the cos threshold for the dry running protection LED COS 4 1 F u n...

Page 25: ...ump ON lumineaza intermitent In aceste conditii PresSystem nu opreste pompa imediat ci dupa aproximativ 20 secunde After the phase of the first startup the device is ready for automatic operation oper...

Page 26: ...manual utilizare presostat electronic pressystem 26 e s o s t a t P r e s s u r e s w i t c h O p e r a t i o n...

Page 27: ...D DRY RUNNING la versiunea fara cos Protectie supratensiune vers cos Protectie impotriva resetarilor dese sau pentru pierderi in vasul de expansiune ex cand acesta este spart The PresSystem can be con...

Page 28: ...i e l e c t r i c B r e a k c u r r e n t In cazul unei pene de curent PresSystem porneste automat pompa ca si cand ar fi la prima utilizare vezi sectiunea 4 In the case of a break current the PresSy...

Page 29: ...manual utilizare presostat electronic pressystem 29...

Page 30: ...ystem 30 5 MOD DE FOLOSIRE OPERATION AND USE 5 1 T a s t a t u r a K e y b o a r d Buton Button Descriere Description 1 Butonul ON OFF Permite pornirea sau oprirea pompei ON OFF button Allows to turn...

Page 31: ...EDIT button is pressed the value will be stored permanently if the ON OFF button is pressed the value will not be stored and it is possible to exit without saving NB The pressure values modified by th...

Page 32: ...este mai mica decat presiunea de Lipsa Apa Led Dry Running PresSystem nu va afisa nici o eroare F6 Dispozitivul este configurat sa foloseasca modul de operare tip Presostat PresSystem with an externa...

Page 33: ...le to exit without saving 5 LED PUMP ON Led Activ pompa functioneaza Led Stins pompa este oprita Led Intermitent pompa functioneaza dar dispozitivul se va opri pentru a permite atingerea presiunii nec...

Page 34: ...be managed automatically by the device 7 LED PR RESTART Led Activ afiseaza presiunea minima de repornire Daca este apasat butonul EDIT presiunea minima poate fi modificata Led Stins nici o actiune Led...

Page 35: ...lorii LED CURRENT Led On displays the measured current If the EDIT button is pressed the current value is displayed Led Off no action Led Blinking the measured current has exceeded the current thresho...

Page 36: ...ctiv afiseaza starea intrarii auxiliare J5 0 indica contactul J5 deschis 1 indica contactul J5 inchis LED FLOAT SWITCH Led On displays the status of the auxiliary input J5 0 the contact J5 is open 1 t...

Page 37: ...manual utilizare presostat electronic pressystem 37 5 2 A d m i n i s t r a r e a a u t o m a t a a p a r a m e t r i l o r A u t...

Page 38: ...unea de intrare in protectia Lipsa Apa Presiunea maxima poate fi deasemenea setata si manual de catre utilizator asigurand un control mai corect in functie de instalatie The PresSystem automatically u...

Page 39: ...Valorile presiunii modificate de catre utilizator nu vor mai fi actualizate automat installation NB The pressure values modified by the user will not be managed by the device automatically 5 3 A d m i...

Page 40: ...al de catre utilizator asigurand un control mai corect in functie de instalatie NB Valorile presiunii modificate de catre utilizator nu vor mai fi actualizate automat The pressure can also be set manu...

Page 41: ...e the and keys to set the desired value The value will be stored pressing the EDIT button again the led stops flashing If you don t want to save the new value press the ON OFF button The modified para...

Page 42: ...If a fault is present the PresSystem turns on and off all the LEDs and displays the error code of the fault Error codes Cod Code Eroare Error Descriere Description 01 Lipsa apa No Water Presiunea mas...

Page 43: ...eck if it is blocked 02 Lipsa vas de expansiune No expansion tank PresSystem sesizeaza lipsa unui vas de expansiune daca pompa porneste foarte des Ce trebuie facut 1 Pentru a reporni sistemul si a ies...

Page 44: ...ence of water 04 Presiune prea mica Low pressure Presiunea masurata de PresSystem in instalatie la Prima Utilizare este sub 1 bar Ce trebuie facut 1 Pentru a reporni sistemul si a iesi din eroare treb...

Page 45: ...riction or locking of the pump Check that the pump is used under the conditions prescribed 06 Vers Cos Curent de varf maxim Max pick current Curentul absorbit al pompei masurat de PresSystem este mai...

Page 46: ...ss again ON OFF button to restart the system SOLUTIONS Check for water presence Check there is no air in the system Reset the correct priming pump function If there is a filter check if it is blocked...

Page 47: ...tat electronic pressystem 47 mai mica decat presiunea maxima masurata de PresSystem pressure changed by the user is less than the maximum pressure measured by the device 7 1 I n l o c u i r e P l a c...

Page 48: ...manual utilizare presostat electronic pressystem 48 S e n z o r d e p r e s i u n e R e p l a c e m e n t B o a r d P r e s s u r e...

Page 49: ...ading pressure Inlocuirea placii electronice 1 Desurubati surubul 1 si inlaturati capacul cablurilor Figura 2 2 Desurubati suruburile 2 si 3 ale capacului frontal Figura 3 3 Dupa inlaturarea tuturor s...

Page 50: ...re dreapta in punctele 6 si 7 Figura 4 5 Inlaturati cu grija cablul tastaturii din conectorul 8 Figura 5 4 To remove the flat cable of the keyboard you need to release the lock that stops the cable by...

Page 51: ...ronice Figura 7 Pentru montarea placii noi folositi instructiunile in sens invers descrierii de mai sus 6 Unclip the connector of the pressure sensor 9 Figura 6 7 Unscrew the screw 10 and 11 of the el...

Page 52: ...2 3 on the replacing electronic board and then continues to unclip the pressure sensor connector 1 Figura 8 2 Unscrew the screws 2 and 3 of the sensor ring 4 Figura 8 3 Once the screws and the sensor...

Page 53: ...manual utilizare presostat electronic pressystem 53 Figura 10 Figura 11 8...

Page 54: ...manual utilizare presostat electronic pressystem 54 Via Maestri del Lavoro 25 27 50013 Campi Bisenzio FI ITALY Tel 39 055 88 77 672 39 055 88 77 372 39 055 88 79 276 Fax 39 055 88 77 068...

Reviews: