OM-210 089 Page 18
SECTION 4 − OPERATION
4-1.
Controls
1
Voltage Switch
The higher the selected number,
the thicker the material that can be
welded (see weld setting label in
welding power source or Sections
4-2 and 4-3, as applicable). Do not
switch under load.
2
Voltage Switch - Purge “0”
Position
In purge position, fan runs but
there is no weld output.
3
Wire Speed Control
Use control to select a wire feed
speed. As Voltage switch setting
increases, wire speed range also
increases (see weld setting label in
welding power source or Sections
4-2 or 4-3, as applicable).
4
Power Switch
Ref. ST-205 387
2
1
3
MAX.
(STEEL)
THICKNESS
MATERIAL
18−24 GA.
.022−.047
.062
16 GA.
.125
11 GA.
1
0
WIRE
FEED
SPEED
2
3
4
WELD
VOLTS
10
9
8
7
6
5
O
OFF
INPUT
POWER
ON
Do not switch
while welding
Ne pas commuter
durant LeSoudure
1
2
3
4
PURGE
4
Summary of Contents for GA16C2
Page 2: ......
Page 4: ......
Page 31: ...OM 210 089 Page 27 ST 205 423 B 53 53 Figure 6 3 Circuit Diagram For 230 VAC Model ...
Page 41: ...OM 210 089 Page 37 Notes ...