Mac Medical WT0004 Instruction Manual Download Page 4

Instruction Manual

MAN-070

4

www.macmedical.com

GENERAL SPECIFICATIONS

Power Requirements:

120 Volt, 60 Hz, single phase, 15 amp GFCI protected electrical outlet, installed per local building codes, and 

provides protective grounding.

UL Approved: 

All individual electronic components are UL approved and/or recognized.

Table Installation

Work Tables with the Electronic Height Adjustment Option require a power source to operate the hydraulics 

system.
1.  Place the table so that its left side(where its power unit is located) is near a 120 VAC GFI power outlet.
2.  Plug in the table cord.
3.  On the initial start-up, set the maximum and minimum heights on the control pad as shown on page 9 

and 10.

4.  After the initial start-up and control pad setting, thereafter simply use the up or down arrow buttons on the 

control pad to raise or lower the height of the table.

Summary of Contents for WT0004

Page 1: ...N MANUAL Read and understand all of the instructions and safety information in this manual before operating this product MAN 070 REV A 03 2018 2017 MAC Medical Inc WORK TABLES Manual and Electric Heig...

Page 2: ...ns 3 GENERAL SPECIFICATIONS 4 Table Installation 4 UNPACKING INSTRUCTIONS 5 MINIMUM MAXIMUM ADJUSTABLE HEIGHTS FOR A WORK TABLE 6 HEIGHT ADJUSTMENT MANUAL HYDRAULIC PUMP WITH HANDCRANK 7 HEIGHT ADJUST...

Page 3: ...cally friendly adjustable heights adjustable manually or electronically Manual adjustable height range 36 55 Electronic adjustable height range 36 43 H or U brace instead of Under Shelf Full base unit...

Page 4: ...ation Work Tables with the Electronic Height Adjustment Option require a power source to operate the hydraulics system 1 Place the table so that its left side where its power unit is located is near a...

Page 5: ...surfaces with sharp edges IMPORTANT Wear gloves and eyewear during the unpacking operation Retain all shipping materials until the table is completely unpacked and inspected for damage 5 Use tin snips...

Page 6: ...abletop The Maxumim height of a Manual Height Adjust WorkTable is 55 from floor to tabletop Minimum Maximum Adjustable Height Electronic Height Adjustment The Minimum height of an Electronic Adjust Wo...

Page 7: ...Hydraulic Pump with Handcrank Fig 5 6 the Handcrank can be folded to disappear under the table 1 Crank the table to the desired height 2 Pull the Crank outwards then rotate downward to fold the handle...

Page 8: ...s Electrical Specifications 4 Memory Positions Primary Voltage 120V 10A Digital Display of the height Engine Voltage 24 VDC Overload Protection Nominal Rating Approximately 340 VA Thermal Protection S...

Page 9: ...minus e Moving up or down is not possible f Press the S green button to confirm g After the confirmation the display will flash US 036 EU 091 h Use the Up arrow button to move to the upper us 43 EU 10...

Page 10: ...ss the down arrow The table will now move down Checking with a tape measure lower the table down to US 36 EU 91cm c Then hold 2 until it reads 000 Then press S to set It will then display 036 d Hold t...

Page 11: ...Pad must be replaced due to damage first remove the existing Memory Control Pad 1 Unplug the table from its power souce 2 Remove four 1 4 screws attaching the Controller to the table mounting plate Fi...

Page 12: ...the Memory Control Pad to the table mounting plate Fig 11 3 Plug the control pad cable into the round receptacle of the table Power Supply Unit 12 13 4 Plug the table cord back into its power source...

Page 13: ...le will now move down Verify height of table is US 36 EU 91cm with a tape measure 5 Press and hold 2 button until 000 is displayed Press GREEN SET Button Display will now read 036 6 Press and hold UP...

Page 14: ...pads Soft bristle brush Mild detergents Sodium Bicarbonate baking soda Distilled water pH rating 7 alone or with a mild detergent White vinegar in a spray bottle Isopropyl Alcohol Hospital grade non b...

Page 15: ...1 H0135 5 LSS 5 Swivel Caster w Brake 2 All 2 H0090 03 Hydraulic Pump with crank 1 All 1 2 2 The Work Table replacement parts listed on this page have been identified by MAC Medical as serviceable by...

Page 16: ...actory It is the customer s responsibility to inspect the product for packaging damage before signing the BOL This warranty does not apply to products which have been subject to abuse misuse accident...

Reviews: