INSTRUCTION MANUAL
Read and understand all of the instructions and safety
information in this manual before operating this product.
MAN-070 REV A
03/2018
© 2017 MAC Medical, Inc.
WORK TABLES
(Manual and Electric Height Adjust)
Page 1: ...N MANUAL Read and understand all of the instructions and safety information in this manual before operating this product MAN 070 REV A 03 2018 2017 MAC Medical Inc WORK TABLES Manual and Electric Heig...
Page 2: ...ns 3 GENERAL SPECIFICATIONS 4 Table Installation 4 UNPACKING INSTRUCTIONS 5 MINIMUM MAXIMUM ADJUSTABLE HEIGHTS FOR A WORK TABLE 6 HEIGHT ADJUSTMENT MANUAL HYDRAULIC PUMP WITH HANDCRANK 7 HEIGHT ADJUST...
Page 3: ...cally friendly adjustable heights adjustable manually or electronically Manual adjustable height range 36 55 Electronic adjustable height range 36 43 H or U brace instead of Under Shelf Full base unit...
Page 4: ...ation Work Tables with the Electronic Height Adjustment Option require a power source to operate the hydraulics system 1 Place the table so that its left side where its power unit is located is near a...
Page 5: ...surfaces with sharp edges IMPORTANT Wear gloves and eyewear during the unpacking operation Retain all shipping materials until the table is completely unpacked and inspected for damage 5 Use tin snips...
Page 6: ...abletop The Maxumim height of a Manual Height Adjust WorkTable is 55 from floor to tabletop Minimum Maximum Adjustable Height Electronic Height Adjustment The Minimum height of an Electronic Adjust Wo...
Page 7: ...Hydraulic Pump with Handcrank Fig 5 6 the Handcrank can be folded to disappear under the table 1 Crank the table to the desired height 2 Pull the Crank outwards then rotate downward to fold the handle...
Page 8: ...s Electrical Specifications 4 Memory Positions Primary Voltage 120V 10A Digital Display of the height Engine Voltage 24 VDC Overload Protection Nominal Rating Approximately 340 VA Thermal Protection S...
Page 9: ...minus e Moving up or down is not possible f Press the S green button to confirm g After the confirmation the display will flash US 036 EU 091 h Use the Up arrow button to move to the upper us 43 EU 10...
Page 10: ...ss the down arrow The table will now move down Checking with a tape measure lower the table down to US 36 EU 91cm c Then hold 2 until it reads 000 Then press S to set It will then display 036 d Hold t...
Page 11: ...Pad must be replaced due to damage first remove the existing Memory Control Pad 1 Unplug the table from its power souce 2 Remove four 1 4 screws attaching the Controller to the table mounting plate Fi...
Page 12: ...the Memory Control Pad to the table mounting plate Fig 11 3 Plug the control pad cable into the round receptacle of the table Power Supply Unit 12 13 4 Plug the table cord back into its power source...
Page 13: ...le will now move down Verify height of table is US 36 EU 91cm with a tape measure 5 Press and hold 2 button until 000 is displayed Press GREEN SET Button Display will now read 036 6 Press and hold UP...
Page 14: ...pads Soft bristle brush Mild detergents Sodium Bicarbonate baking soda Distilled water pH rating 7 alone or with a mild detergent White vinegar in a spray bottle Isopropyl Alcohol Hospital grade non b...
Page 15: ...1 H0135 5 LSS 5 Swivel Caster w Brake 2 All 2 H0090 03 Hydraulic Pump with crank 1 All 1 2 2 The Work Table replacement parts listed on this page have been identified by MAC Medical as serviceable by...
Page 16: ...actory It is the customer s responsibility to inspect the product for packaging damage before signing the BOL This warranty does not apply to products which have been subject to abuse misuse accident...