background image

 

14 

 

 

 

1.

 

If  you  using  a  controller  with  5  pins  DMX  output,  you  need  to  use  a  5  to  3  pin 
adapter-cable. 

2.

 

At  last  unit,  the  DMX  cable  has  to  be  terminated  with  a  terminator.  Solder  a  120  ohm 
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in 
the DMX-output of the last unit. 

3.

 

Connect the unit together in a ‘daisy chain’ by XLR plug from the output of the unit to the 
input of the next unit. The cable cannot be branched or split to a ‘Y’ cable. DMX512 is a 
very  high-speed  signal.  Inadequate  or  damaged  cables,  solder  joints  or  corroded 
connectors can easily distort the signal and shut down the system. 

4.

 

Each lighting unit needs to have an address set to receive the data sent by the controller. 
The address number is between 0-511 (usually 0 & 1 are equal to 1). 

 
 

Troubleshooting   

Following  are  a  few  common  problems  that  may  occur  during  operation.  Here  are 
some suggestions for easy troubleshooting: 
 

 

The fixture does not work, no light   

o

 

Check the connection of power and main fuse. 

o

 

Measure the mains voltage on the main connector. 

 

Not responding to DMX controller 

o

 

DMX LED should be on. If not, check DMX connectors, cables to see if 

link properly. 

o

 

If  the  DMX  LED  is  on  and  no  response  to  the  channel,  check  the 

address settings and            DMX polarity. 

o

 

If  you  have  intermittent  DMX  signal  problems,  check  the  pins  on 

connectors or on PCB of the fixture or the previous one. 

o

 

Try to use another DMX controller.     

Summary of Contents for MEGA UFO-LZR

Page 1: ...1 MEGA UFO LZR MODE D EMPLOI USER MANUAL...

Page 2: ...tion des Directive Europ ennes suivantes Directive LVD n 2006 95 CE Directive RoHS 2 n 2011 65 UE Directive EMC n 2014 30 EU Conservez ce manuel pour une future consultation Si vous revendez cet appar...

Page 3: ...rder directement le faisceau lumineux La lumi re d un LASER peut causer des dommages permanents aux yeux Cet appareil doit tre install avec un crochet solide et de dimension ad quate au poids support...

Page 4: ...re 1993 Signalisation de s curit et de sant sur les lieux de travail et la norme NF X 08 003 Symboles graphiques et pictogrammes couleurs et signaux de s curit de d cembre 1994 Cette signalisation est...

Page 5: ...4 06 kg 4 4 kg Ce projecteur intelligent respecte les normes europ enne en vigueur EN 2014 30 EU EN 2011 65 EU EN 2014 35 EU Modes de Fonctionnement S lection du Mode de fonctionnement A Utilisation e...

Page 6: ...es touches DOWN et UP s lectionnez l adresse DMX d sir e Appuyez sur ENTER pour valider cette valeur MENU MENU addr A001 A512 DMX512 Address setting Chnd Fast Fast Auto Running Slow Slow Auto Running...

Page 7: ...gree rotation 7 Motor4 0 255 0 180 degree rotation 8 Motor5 0 255 0 180 degree rotation 9 Motor6 0 255 0 180 degree rotation 10 Dimmer 0 255 Linear dimming from dark to bright 11 Strobe 0 9 None 10 25...

Page 8: ...ht 18 Beam Blue 0 255 Blue linear dimmer from dark to bright 19 Beam White 0 255 White linear dimmer from dark to bright 20 Red Laser 0 255 Red Laser linear dimmer from dark to bright 21 Green Laser 0...

Page 9: ...vous que votre prise soit bien aliment e L appareil ne r pond pas ou pas correctement aux commandes DMX o V rifiez vos c bles DMX o V rifiez votre adressage DMX o Essayez un autre contr leur DMX o V r...

Page 10: ...eye and skin exposure to direct or scattered radiation Class III B laser product EN 60825 1 2014 Directive LVD n 2006 95 CE Directive RoHS 2 n 2011 65 UE Directive EMC n 2014 30 EU Please read the in...

Page 11: ...t the device to any dimmer pack To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture Do not look directly at the LASER light beam while the fixture i...

Page 12: ...structions provided in the NF EN 60825 1 standard Such access can be controlled at least when lasers are operating Emissions control the control panel should be placed outside the locations exposed to...

Page 13: ...uick installation with an immediate result The following devices must be selected in dmx mode and address 001 To do this the MEGA UFO LZR must be connected to each other with a DMX XLR cable The desir...

Page 14: ...wn the system 4 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 Troubleshooting Following are...

Page 15: ...Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particular...

Page 16: ...tionen f hren Wenden Sie sich bitte an das n chstgelegene autorisierte technische Kundendienstzentrum Au er der Sicherung befinden sich keine vom Benutzer zu wartenden Teile im Ger t Schlie en Sie das...

Page 17: ...e des Laserprodukts und die Anweisungen der Norm NF EN 60825 1 erg nzt Ein solcher Zugriff kann kontrolliert werden zumindest wenn Laser in Betrieb sind Emissionskontrolle Das Bedienfeld sollte au erh...

Page 18: ...e Adresse 001 haben Dazu m ssen die MEGA UFO LZR mit einem DMX XLR Kabel miteinander verbunden werden Der gew nschte Auto oder Sound Modus muss dann auf dem 1 MEGA UFO LZR ausgew hlt werden und wird a...

Page 19: ...Als u het apparaat aan een andere gebruiker verkoopt zorg er dan voor dat hij deze handleiding ook ontvangt Pak het apparaat uit en controleer het voor gebruik zorgvuldig op transportschade Het is bel...

Page 20: ...geopereerd in een kamer of in een afgesloten of afgebakende locatie Ruimte ingangen en openingen naar buiten mogen niet in de as van een directe straal liggen De vloer moet vrij zijn van obstakels De...

Page 21: ...een situatie waar persoonlijk letsel of schade aan eigendommen kan optreden MOET de werking onmiddellijk worden stopgezet Fabrikanten en detailhandelaren zijn niet verantwoordelijk voor schade veroor...

Page 22: ...e DMX controller Als u een universele DMX controller gebruikt om de units te besturen moet u het DMX adres van kanaal 1 tot 512 instellen om de units DMX signalen te laten ontvangen Druk op MENU zoek...

Reviews: