Random
Master status: Auto run and send DMX
signal to slave
Auto
DMX Address
001-512
Press “OK” key enter into edit status,
then press “UP” “DOWN” to change
DMX address. press “OK” key save and
exit edit status.
Channel Mode
Std.14CH
Standard 14 Channel Mode
Top Lamp Temp
001-110
Sound Regulator
-006 --- +006
Invert Pan
OFF
ON for starting and ending , the default
is OFF.
ON
Invert Tilt
OFF
ON for starting and ending , the default
is OFF.
ON
Pan-Tilt Swap
OFF
ON
Exchange Pan/Tilt channel (include
Pan/Tilt Fine)
Pan-Tilt Encoder
ON
Use encoder (optocoupler) to
determine out of step and automatically
correct position
OFF
Correct position without encoder
(optocoupler)
RDM
ON
Support RDM function
OFF
No DMX Signal
KEEP
Continue running as it is
CLEAR
All motors return to the position and
stop running.
Display
ON
OFF
Lamp On@Startup
OFF
ON
Load Default
Press the "OK" button to see the
confirmation dialog, press "OK" again
The key restores the default settings
Manual Control