Then,  clean  the  surface  thoroughly  of  any  debris  and  dirt.  Once  the 
surface is clean the next step is to apply the foam gasket provided

 

foam 

gasket that is installed on the roof to create a seal between the roof and 
the AC unit. If your roof is not flat and have cantrails, fill in between the 
roof reinforcement with bully

 

tape to get a plan surface. 

  

 

 

 

 

 

Install all shock absorbers on the foam gasket   

Summary of Contents for RVSC 12000

Page 1: ...Mabru Rooftop RVSC 12000 DC 12v Manual 2021 VERSION 1 0 MABRU POWER SYSTEMS Address 1105 Old Griffin Rd Dania Beach FL 33004Phone 1 888 818 2814Email sales mabrumarine com ...

Page 2: ...escription Parameters Page 3 4 Componements and Controls Page 5 6 Error Codes and Troubleshooting Page 6 Low Over Voltage Troubleshooting Page 7 16 Installation Instructions Page 16 18 Wiring Diagrams Page 19 21 Disclaimers Safety Precautions Page 22 Warranty ...

Page 3: ... been designed to be sleek aerodynamic aesthically beautiful and efficient 12V 24V systems in its class The 12V 24V rooftop unit provides cool fresh air within 15 seconds creating a space that is cool and comfortable This unit is desinged to be ran inside a RV Van buses mobile homes trucks and campers and in any application similar Parameters ...

Page 4: ...Condenser Fan 3 Outdoor and Indoor unit separator Mounting plate 4 Skylight Panel 5 Return Inlet 6 Display 7 Supply Outlet 8 LED Lights On Off Switch Blower Speed Switch Mode Selector Temperature Increase Infrared Receiver Temperature Decrease Light Switch ...

Page 5: ...ient rate 4 To view the current voltage being used by the unit Simply press and hold the M button for 6 seconds and the voltage value will appear on the screen To exit the current voltage mode do not press any buttons for 6 seconds and the unit will return the main menu automatically 5 The display will always show the set temperature The possible temperate ranges on the unit vary between 5 40 degr...

Page 6: ...fan failure Short circuit of motor poor contact of plug E7 Motor phase lost Compressor terminals burnt out or compressor short circuit E9 PER Pressure switch protection Pressure switch may be damaged and needs replacement OPE Open temperature sensor Check is plug disconnected or the wire is broken or damaged LU Low voltage SHr Temperature sensor short circuit Replacement of temperature sensor AC C...

Page 7: ...rvoltage value can be adjusted between the range of 9 28 volts When the battery voltage is lower than the under voltage protection values the system will stop working and the error code LU will be displayed on the main display To clear the undervoltage error power the unit off then power back on Steps to adjust undervoltage protection value 1 Power on unit and locate the button on the display 2 Pr...

Page 8: ...he unit can be installed into an existing standard size 14 x 14 opening with some disassembly reassembly or if you want to be more simple and not perform this disassembly reassembly you can choose to cut a hole using the template provided with your unit If you want to install the unit into an existing standard size 14 x 14 opening please review the following steps A Remove the interior plastic cov...

Page 9: ...penings on the bottom of the AC unit are over the cut out area of your roof You should be able to see each of these openings on the bottom of the AC unit from inside your van These provide the air flow into and out of the unit so they cannot be blocked by the sheet metal of your van roof See photos below showing ...

Page 10: ...irector and the interior plastic trim and continue with the standard installation procedure If you choose to not perform this disassembly reassembly ant to use the template 20 1 8 x 14 1 2 note that cutting the hole may require power driven tools and should only be done by trained professionals 2 Once a hole has been cut you must smooth the edges and paint it with an anti rust paint ...

Page 11: ...ep is to apply the foam gasket provided foam gasket that is installed on the roof to create a seal between the roof and the AC unit If your roof is not flat and have cantrails fill in between the roof reinforcement with bully tape to get a plan surface Install all shock absorbers on the foam gasket ...

Page 12: ... as Proflex or 5200 if you want make sure of the waterproof of the seal C Once the weather proofing is installed the unit may be installed Ensure that a gap of 25mm is present between the mounting plate and the outside roof to allow for adequate ventilation for the outside portion of the rooftop AC D Once in position the unit is ready to be mounted to the roof using the 4 securing screws and the b...

Page 13: ...ights or not If you design and decide to create your own return grill trim on the interior as below you will need to keep enough air flow and take care to not have any restriction to avoid any problems evaporator frozen If you keep the outer trim panel with the 4 LED lights you will fix it with bolts under the LED lights and the interior LED lights may be installed using the wiring harnesses inclu...

Page 14: ...13 Once the lights are installed and the unit is connected to a power source The unit may be turned on ...

Page 15: ...ge wire positive and negative for connections ample length to reach the unit and alternator A Mount your DC to DC charger and Lithium Iron batteries in the desired location securely Then connect your positive and negative terminals to the engine battery or alternator and run them to the positive and negative terminals of the DC to DC charger B From the DC to DC charger you will run the cables to a...

Page 16: ...wiring harnesses that are installed on the unit Lastly once all connections are made verify that all the connections are tight and secure Failure to do so may result in equipment damage injury or fire Once verified you may power on the system and begin operating your rooftop air conditioner ...

Page 17: ...16 Wiring Diagram 12 24V ROOFTOP AC WIRING DIAGRAM ...

Page 18: ...17 12 24V ROOFTOP AC AND SOLAR WIRING DIAGRAM ...

Page 19: ...18 12 24V ROOFTOP AC SOLAR SHORE POWER WIRING DIAGRAM ...

Page 20: ...utube com user aamabru Users must strictly follow the video and its instructions If the user fails to install the Rooftop 12V 24V Air Conditioning unit according to steps provided in the user manual and installation video the results could lead to equipment failure damage injury or death The user will bear full responsibility for such incidents and Mabru Power Systems will not be held liable for d...

Page 21: ...rescribed in the manual Issues such as equipment damage or injury may occur and Mabru Power Systems will bear no responsibility and warranty will be voided 4 The user agrees to this disclaimer after purchasing the product ...

Page 22: ...ar the engine or any other type of internal combustion engine tanks LPG CPG cylinders regulators valves or fuel line fittings Failure to follow this precaution could result in serious injury or death 2 Installing and servicing of this unit can be hazardous due to the systems pressures and electrical components 3 When working on this unit always observe the precautions prescribed in this manual tag...

Page 23: ...ted Warranty is made in lieu of all other express warranties obligations or liabilities on the part of Mabru In those instances in which Mabru chooses to make a cash refund of the original purchase price such refund shall affect the cancellation of the contract of sale without reservation of rights on the part of the owner Such refund shall constitute full and final satisfaction of all claims whic...