![MABIS 40-270-000 MABISMist II Mabismist™ Ii Download Page 4](http://html.mh-extra.com/html/mabis/40-270-000-mabismist-ii/40-270-000-mabismist-ii_mabismist-ii_685074004.webp)
• Keep your eyes away from the output of
medication mist.
• Change the water after each use.
• The maximum capacity of the medicine cup
is 8 ml. and should not be overfilled.
• Dilute dense medications or medication
volumes 2 ml. or less with distilled water or
saline solution to obtain a volume of at least
4 ml.
• Do not use this unit while operating a
vehicle.
• If any discomfort or abnormality occurs,
stop using the unit immediately.
Storage Cautions
• Do not store the unit in direct sunlight, high
temperature or humidity.
• Keep the unit out of reach of small children.
• Always keep the unit unplugged while not
in use.
Cleaning Cautions
• Check the medication cup, air filter, masks,
gasket, extension tube, mouth and nasal
pieces and air filter before each use. Dirty
or worn parts should be replaced.
• Do not immerse the unit in water. It may
damage the unit.
• Disconnect the unit from the electrical outlet
before cleaning.
• Clean all necessary parts after each use as
instructed in this guidebook.
Battery Cautions
• Do not use the battery with equipment
other than your MabisMist™ II Ultrasonic
Nebulizer, or attempt to modify it for
other use.
• Do not store the battery in direct sunlight,
high temperature or high humidity.
• Avoid placing the battery on metal or wet
surfaces or inside a metal box. This may
short-circuit the battery’s positive and
negative contact causing the battery to
heat up or explode.
Cleaning Procedures
It is important to clean your Nebulizer before
the first time it is used and after each use.
Remember: Disconnect the unit from the
electrical outlet and never immerse the unit in
water.
Cleaning the parts:
The mouth piece, nasal piece, gasket, masks,
extension tube, cover, medicine cap, air filter
cover, air filter, and fan should be cleaned
with a mild detergent or commercially avail-
able disinfectant. (Use a non-metal tool to
carefully remove the air filter cover, air filter
and fan.) Thoroughly rinse each part and
allow to completely air dry before using.
Cleaning the main body:
The main body should be cleaned with a soft
cloth moistened with a non-abrasive cleanser
and water.
Five modes of medication
delivery:
Mouthpiece #1,
Connect mouthpiece
to the cover.
Extension tube
with mouthpiece #2,
Connect one end of
the extension tube to
mouthpiece #2.
Connect the other
end to the cover.
Extension tube
with adult mask,
Connect one end of
the extension tube
to the adult mask.
Connect the other
end to the cover.
Extension tube
with child mask,
Connect one end of
the extension tube
to the child mask.
Connect the other
end to the cover.
Nasal piece,
Connect nasal piece
to the cover.