background image

   

 

SERVICE MANUAL

 

Model:CHM200PB1 

21

Issue      2017-6-03 

Rev.     REF1706S004V0

 

8-2. Abnormal phenomena 

8-2-1. Compressor doesn’t start   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Com pressor 

doesn

t start

               
                W hether lighting 
           and display system is 
                       normal

                   Whether the 
           grade of thermostat is 
                          on 0

 W hether the  

resistance of compressor is 

infinite or 0

Whether the 

starting current is 

about 5A

W hether PTC starter

 

resistance between running jack 

and starting jack is 16-50 O

Measure whether 

two ends of heat protector 

is through

W hether the finger 

of multimeter swing  to 0 quickly 

and then swing back slowly 

when measuring two 
poles of capacitance

Whether 

compressor

 pin is tight, 

contact 
is good

W hether input 

and output voltage of main 

control board is normal

W hether each 

contact of main control board 

is normal

Tighten each 

contact and test machine

 again

Y

Trouble of lighting and display system

Adjust the grade according to fact

Compressor is open circuit or short 

circuit

Inner trouble of compressor 

If it is infinite or 0, then the starter is 

out of work.

Heat protector is out of work

Capacitance is out of work

Insert again, electrify and test

Main control board is out of work

Change for a new com

pres
sor

Y

N

N

N

Y

Y

Y

Y

Y

N

Y

Y

Y

N

N

N

N

N

Compressor doesn

t start 

sometimes because the 

temperature in case is 

between starting and stop 

temperature, should pay 

attention when do test

Adjustment of thermostat
Temperature of 
environment
>30

       1-3 grade

16-30

      3-5grade

<16

       5-7grad

Summary of Contents for CHM200PB1

Page 1: ...signed for use by the general public It dose not contain warnings and cautions to advice non technical individuals of potential dangers in attempting to service a product Product powered by electricit...

Page 2: ...Disassembly 11 4 1 Door assembly Door hinge hinge cover 11 4 2 Compartment Grill assembly 11 4 3 Control panel assembly Panel cover board knob indicator light 12 4 4 Thermostat assembly 12 Chapter 5 C...

Page 3: ...avoid an electrical shock hazard 3 In the case of a live line test insulating gloves should be worn to avoid potential electrical shock 4 Confirm the rated current voltage and capacity before testing...

Page 4: ...you may be glued to the surface 14 Pull out the plug of power supply during clearance or power outage Wait at least five minutes to resume the power supply in order to prevent damage to the compressor...

Page 5: ...SERVICE MANUAL Model CHM200PB1 5 Issue 2017 6 03 Rev REF1706S004V0 A reference guides us to other places in this binder or in this manual where we will find additional information on a specific topic...

Page 6: ...n h 35 Defrosting Manual Automatic Manual Kind of coolant R134a R600a R600a 56g 3 Technical data Voltage frequency V Hz 220 60 Input power currency W A 100 1 5 Lenght of cable incl plug cm 160 165 Tem...

Page 7: ...SERVICE MANUAL Model CHM200PB1 7 Issue 2017 6 03 Rev REF1706S004V0 2 2 External views Door Cabinet Control penel...

Page 8: ...e freezer on a floor strong enough to support it fully loaded 3 When moving freezer never tilt it more than a 45 degree angle This could damage the compressor and the sealed system 4 If freezer is til...

Page 9: ...the freezer Defrosting usually takes a few hours To defrost faster keep the freezer door open When done push the drain dial in and turn the arrow to the up position Re plug the drain plug inside the f...

Page 10: ...ot practical wring excess moisture out of sponge or cloth when cleaning in the vicinity of switches lights or controls An open box of baking soda in the freezer will absorb stale freezer odors Change...

Page 11: ...hinge hinge cover 1 Unscrew the hinge cover screw with screwdriver take away the top and bottom cover by pull it and then unscrew the screws on the hinge so the whole hinge could be moved 4 2 Compart...

Page 12: ...nector inside when the clip falls off the cabinet and take off the control panel and the connective wire cord with an acutilingual plier 4 4 Thermostat assembly First take off the knob Use turnbuckle...

Page 13: ...evel you require between Min slight cooling and max Lowest temperature If the appliance is equipped with indicator lights the following guide explains what is meant by each light up Green CONTROL The...

Page 14: ...the Freezer 1 Clean the inside of the freezer with a mild solution of baking soda and water 2 Connect cord to power outlet 3 On models with a Temperature Monitor or High Temp Alarm Switch set the swi...

Page 15: ...6 System flow principle 6 1 Refrigeration flow chart The refrigeration system of direct cooling single system cooler belongs to the category of a single temperature and single control refrigerating sy...

Page 16: ...SERVICE MANUAL Model CHM200PB1 16 Issue 2017 6 03 Rev REF1706S004V0 6 2 Refrigeration flow scenograph...

Page 17: ...SERVICE MANUAL Model CHM200PB1 17 Issue 2017 6 03 Rev REF1706S004V0 Chapter 7 Circuit diagram 7 1 Brief principle diagram...

Page 18: ...SERVICE MANUAL Model CHM200PB1 18 Issue 2017 6 03 Rev REF1706S004V0 7 2 Wiring diagram...

Page 19: ...left open Check to see if package is holding door lid open Too frequent or too long door lid openings Reduce the time of opening the door lid Temperature control set too cold See About the operation...

Page 20: ...s run for too long on some models About the operation of the freezer Moisture forms on outside of cabinet Not unusual during periods of high humidity Wipe surface Interior light does not work on some...

Page 21: ...tight contact is good Whether input and output voltage of main control board is normal Whether each contact of main control board is normal Tighten each contact and test machine again Y Trouble of li...

Page 22: ...SERVICE MANUAL Model CHM200PB1 22 Issue 2017 6 03 Rev REF1706S004V0 8 2 2 Poor cooling...

Page 23: ...M200PB1 23 Issue 2017 6 03 Rev REF1706S004V0 Chapter 9 Attachment 9 1 The main components datasheet No Spare parts Model The main parameters Remark 1 Compressor ETY80XL Power 220V 60Hz Refrigerating c...

Reviews: