15
15
Swim Spa
Electrical Requirements:
240 volt, 60 Hz, single phase, 60 amp.,
•
4-wire service (line 1, line 2, neutral,
and ground or,
*40 Amp Option
Note: The heater can be activated only with
the pump on low speed. Only the spa light
can be operating at the same time without
disabling the heater. See your authorized
MAAX Spas dealer to select this option.
Spas installed for 240 volt, 60 Hz, single
phase operation require a 4-wire, 60 amp
240 volt sub-feed in non-metallic pipe to the
spa equipment compartment (line 1, line 2,
neutral and ground). A green colored termi-
nal (or wire connector marked “G”, or “GR”, or
“Grounding”) is provided in the control box.
To reduce the risk of electrical shock, connect
this terminal or connector to the grounding
terminal of your electrical service or supply
panel with a continuous green insulated cop-
per wire equivalent to the circuit conductor
supplying this equipment, but no smaller
than No. 12 AWG. A second pressure wire
connector is provided on the surface of the
control box for bonding to local ground
points. To reduce the risk of electrical shock.
This connector should be bonded with a No.
6 AWG copper wire to any metal ladders,
water pipes, or any metal within 5 feet (1,5m)
of the spa.
Note: Copper wire is strongly recommend-
ed for all electrical connections.