When instructions are given to “press a button” any of the following can be done:
• Navigate to the desired item on any Screen. When the desired item is highlighted, press the Select Button.
• Press the button for that device while on the Shortcuts Screen, if the device is one of the 4 functions available.
PROGRAMMING, ETC.
The Settings Screen is where all programming and other spa behaviors are controlled. This screen has several features that can be acted on directly.
These features include Temp Range, Heat Mode, and Invert Panel. When one of these items is highlighted, the Select Button is used to toggle between
two settings.
All other menu items (with an arrow pointing to the right) go to another level in the menu.
PRESS-AND-HOLD
If an Up or Down button is pressed and held when an item in a Menu List is highlighted, the list can be scrolled quickly from top to bottom. The scroll
bar on the right side of the screen indicates the relative position of the highlighted item in the list.
DUAL TEMPERATURE RANGES
This system incorporates two temperature range settings with independent set temperatures. The specific range can be selected on the Settings screen and
is visible on the Main Screen in the upper right corner of the display.
These ranges can be used for various reasons, with a common use being a “ready to use” setting vs. a “vacation” setting.
Each range maintains its own set temperature as programmed by the user. This way, when a range is chosen, the spa will heat to the set temperature
associated with that range.
High Range may be set between 80°F - 104°F (26˚-40˚C).
Low Range may be set between 50°F - 99°F (10˚-26˚C).
Freeze Protection is active in either range.
HEAT MODE - READY VS. REST
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is known as the “heater pump.” The
heater pump can be either a 2-speed pump (Pump 1) or a circulation pump. If the heater pump is a 2-Speed Pump 1, READY Mode will circulate water every
1/2 hour, using Pump 1 Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display. This is known as
“polling.” REST Mode will only allow heating during programmed filter cycles. Since polling does not occur, the temperature display may not show a current
temperature until the heater pump has been running for a minute or two. While Pump 1 High can be turned on and off, Pump 1 Low will run until set
temperature is reached, or 1 hour has passed.
CIRCULATION MODE
If the spa is configured for 24HR circulation, the heater pump generally runs continuously. Since the heater pump is always running, the spa will
maintain set temperature and heat as needed in Ready Mode, without polling. In Rest Mode, the spa will only heat to set temperature during
programmed filter times, even though the water is being filtered constantly when in Circulation Mode.