33
33
Swim Spa
Automatic Time Outs
Your
swim spa
is equipped with an
automatic Time Out feature designed to
protect both the equipment and the user.
For your safety and to reduce unnecessary
use of the pumps and lights, the Time
Out feature turns selected accessories off
automatically, as follows:
EQUIPMENT SAFETY FEATURES
Accessory
Mode Shuts off in...
Pump 1
Low
4 hours
Pump 1
High
15 minutes
Pump 2
Low
15 minutes
Pump 2
High
15 minutes
Pump 3
Low
15 minutes
Pump 3
High
15 minutes
Lights
1 hour
Common LCD Equipment Safety Messages and Trouble Shooting
The following table describes the most common messages, possible causes, and corrective
actions you may need to take:
If the LCD
displays...
OHH
OHS
HFL
Indicates...
Overheat - one
of the sensors
has detected
water tempera-
ture of 118°F+
(48°C+) inside
the heater
Overheat
- One sensor
has detected
temperature of
swim spa water
entering heater
to be 108°F+
(42°C+)
Heater flow
problem
What happens...
Swim spa heater
will automatically
shut down until
temperature falls
below 108°F+ (42°C+)
Swim spa heater will
automatically shut
down until
temperature falls be-
low 108°F+ (42°C+)
Heater will shut
down while swim spa
continues to function
normally
Possible cause...
- Low speed pump
operating for an ex-
tended period of time
- Programming error
causing continuous
filtering
- Faulty Pump
- Low speed pump
operating for an
extended period
of time
- Programming error
causing continuous
filtering
- Plugged filter
- Low water
Corrective action...
- Make sure slice valves
are open
- Reprogram to ensure
time cycles are not
overlapping
- Contact dealer if
problem persists
- Open all jets
- Make sure slice valves
are open
- Reprogram to ensure
time cycles are not
overlapping
- Contact dealer if
problem persists
- Open all jets
- Remove filter and clean
- Add water
- Open all jets
- Contact dealer