dot2 

Node4  

 

Data 

 

Transport 

 

Safety 
Instructions 

 

Limitation 

 

Quickstart  
Connect 

 

Quickstart  
ON / OFF 

 

Maintenance 

 

Conformity 

 

31 

Connectivity

 

 

 

RJ45 Ethernet socket  

Connect a PC /Laptop or dot2 console 

4 x DMX OUT (XLR 5 pin)  

Power  

  100 

 240 V

~

 50/60 Hz   Automatic operation, no switching necessary! A C13 / C14 

  connector is required. The cable must be fitted with a shock-proof plug and must 
  meet the local requirements. 

Main switch 

 

to turn on or off the device 

 
 

 

 

MENU 

button   

to switch the menu  

Summary of Contents for dot2 XL-B

Page 1: ...dot2 Node4 QuickMAnual XVII 04 deutsch english Art Nr 1285M 00163...

Page 2: ...M A LIGHTING...

Page 3: ...Der dot2 Node4 ist f r den Tour Alltag aber auch f r Installationen konzipiert und daher mit einem robusten Stahlgeh use ausgestattet Neben einem Men Knopf befinden sich auf der Vorderseite f r eine...

Page 4: ...uf einem PC oder Laptop installiert sein muss oder in Verbindung mit einer dot2 Konsole betrieben werden Transport Betrieb und Wartung d rfen nur von Personen ausgef hrt werden die f r die jeweilige T...

Page 5: ...BASE T X Zum Anschluss an einen PC oder Laptop direkt oder ber einen Switch Channels 2048 Channels 4 x 512 Channels 2 TFT Farbmonitor Kann nur zusammen mit einem Laptop PC mit installierter dot2 onPC...

Page 6: ...om technischen Standard des jeweiligen Einsatzortes Stromversorgung Sicherheitshinweis Die Montage des Steckers darf nur durch Fachpersonal ausgef hrt werden Anschlussleistung max 25 VA Erforderlicher...

Page 7: ...nicht auf Oberfl chen die aus Stabilit tsgr nden daf r nicht geeignet sind Ein Verwinden des Geh uses unbedingt vermeiden Beim Transport Temperaturen und Luftfeuchte beachten Die zul ssigen Werte dem...

Page 8: ...I 0 Vorsicht Warnung vor einer Gefahrenstelle Warnung Warnung vor Gef hrlicher elektrischer Spannung Hauptschalter AN AUS Wechsel strom AC Das Ger t muss separat entsorgt werden Befolgen Sie alle Ma...

Page 9: ...Wartung Konformit t Warnhinweise Die Wartung des Ger tes darf ausschlie lich durch geschultes Personal durchgef hrt werden da beim ffnen und oder Entfernen von Abdeckungen spannungsf hrender Teile fr...

Page 10: ...utzkontaktsteckdosen Dies ist eine Schutzma nahme die unbedingt eingehalten werden muss Sollte der Stecker nicht in die Steckdose passen z B bei veralteten Steckdosen muss die Dose von einem Fachmann...

Page 11: ...euchte Betrieb 20 bis 90 relative Luftfeuchtigkeit keine Betauung Lagerung Transport 10 bis 90 relative Luftfeuchtigkeit keine Betauung Umgebung Bitte alle Sicherheitshinweise beachten Das Ger t nur i...

Page 12: ...ner dot2 Konsole 4x DMX XLR 5 pin POWER Netzanschluss 240 V 50HZ 100V 60Hz USA Canada Das Netzteil passt sich automatisch an die Netzspannung an Ein C13 C14 Stecker ist erforderlich Das Kabel muss mit...

Page 13: ...hannelzahl von 2048 Channels beachten Univers Nummern 1 4 oder 5 8 dem jeweiligen DMX Port A B C und D zuordnen und die korrekte Zuordnung der in der Konsole eingestellten Patch Nummern Z B 1 1 oder 2...

Page 14: ...eit Betriebsgrenzen Quickstart Connect Quickstart ON OFF Wartung Konformit t Connect den Node mit einer Konsole oder einem Laptop verbinden PC oder Laptop mit installierter dot2 onPC Software dot2 XL...

Page 15: ...MA dot2 Node4 zeigt nur die wichtigsten Informationen Zum vollst ndigen Konfigurieren ist unbedingt eine dot2 Konsole oder die Software dot2 onPC erforderlich HINWEIS kein Update n tig da der Node na...

Page 16: ...werkseitig fest eingetragen und kann nicht ge ndert werden Kollisionen durch eine versehentlich mehrfach vergebene IP Adresse sind dadurch unm glich DMX Kabel an der R ckseite anschlie en fertig Dabei...

Page 17: ...IP Adresse Die Adresse wird automatisch erzeugt und kann nicht ge ndert werden Jeder dot2 Node4 bekommt werkseitig eine individuelle IP Adresse zugewiesen somit besteht keine Gefahr einer Kollision d...

Page 18: ...onformit t Display Nach dem Einschalten erscheint im Display das Start Men Den Button MENU solange gedr ckt halten bis das gew nschte Men ffnet Reset Mode Der dot2 Node4 wird zur ckgesetzt alle Einste...

Page 19: ...charfe Reiniger verwenden Darauf achten dass die ffnungen f r die K hlluft frei sind Je nach Umgebungsbedingung ist es ratsam das Ger t alle 2 5 Jahre durch einen autorisierten Service reinigen zu las...

Page 20: ...l rt dass das Produkt Produktkategorie Kontrollger t Produktnamen dot2 Node4 den folgenden Richtlinien sowie den harmonisierten Normen entspricht Sicherheit EN60065 EN60950 1 LVD 2014 35 EU EMV EMC 20...

Page 21: ...grammieren am Laptop oder PC Mit der dot2 3D Software kann es zum perfekten Designstudio erg nzt werden Und ist eine M glichkeit den dot2 Node4 als echte Licht Konsole zu nutzen Die dot2 onPC und dot2...

Page 22: ...einigen Spezialit ten z B Touch Command Screen ist die dot2 Serie besonders f r kleine und mittlere Projekte in der Licht Szene ger stet Alle Kommandotasten haben innerhalb der dot2 Serie die gleiche...

Page 23: ...gnals to control lights Optimised for touring and installations purposes both have a rugged steel housing for a long life even under harsh conditions The front panel offers a menu button and a 2 colou...

Page 24: ...on a PC or laptop or connected to a dot2 console Transport operation and maintenance must be performed only by persons who are qualified for the activity The safety and operating limits must be respec...

Page 25: ...Network connector 10 100 BASE T X For connection to a PC or laptop directly or via a switch Channels 2048 Channels 4 x 512 Channels 2 TFT color monitor Can only operated together with a laptop PC wit...

Page 26: ...ired plug connector Must meet the standard in the respective country Power source The socket should be serviced by qualified personnel only Power input max 25 VA Required connector type Suitable for R...

Page 27: ...es that are for reasons of strength or stability unsuitable for this purpose Do not twist the body Please be aware of temperature and humidity during transport Limits see chapter Safety and Environmen...

Page 28: ...ormity 27 Symbols and warning labels I 0 Caution Danger Area Warning Danger of electric shock Supply voltage ON OFF Alternating current AC Dispose of as hazardous waste Follow any instructions that ar...

Page 29: ...onnect Quickstart ON OFF Maintenance Conformity 28 Electric shock warning The unit should be serviced by qualified personnel only as live parts may be exposed when opening and or removing coverings be...

Page 30: ...rvice technicians Do not use any high power walkie talkies or cellular phones near the unit The unit is provided with a safety plug This plug can only be used with safety sockets These precautions sho...

Page 31: ...0 C up to 50 C 14 F up to 122 F Humidity Operation 20 up to 90 relative humidity no condensation Storage Transport 10 up to 90 relative humidity no condensation Environment Follow all the IMPORTANT SA...

Page 32: ...45 Ethernet socket Connect a PC Laptop or dot2 console 4 x DMX OUT XLR 5 pin Power 100 240 V 50 60 Hz Automatic operation no switching necessary A C13 C14 connector is required The cable must be fitte...

Page 33: ...1 1 1 17 1 33 Patch e g 2 1 2 17 2 33 Note the maximum channel number of 2048 channels Assign Univers numbers 1 4 or 5 8 to each DMX port A B C and D and be carefull of the correct assignment of the...

Page 34: ...fety Instructions Limitation Quickstart Connect Quickstart ON OFF Maintenance Conformity 33 Connect connect the node to a console or a laptop dot2 XL F dot2 XL B or dot2 core PC or Laptop with install...

Page 35: ...ill only show the most important settings For configuring a node you have to use a dot2 console or the dot2 onP software Note no update is required because the node after connecting the device always...

Page 36: ...nit of the dot2 family and cannot be changed Collisions by accidentally multiple assigned IP address are therefore impossible Connect DMX cable to the back ready Notice of the assignment of DMX ports...

Page 37: ...e default entry Hostname Version Here the version 1 0 137 6 is loaded IP Address The address is automatically generated and cannot be changed Each dot2 Node4 gets factory assigned a unique IP address...

Page 38: ...N OFF Maintenance Conformity 37 Display After switching on the start menu is displayed MENU button hold it down until the desired menu opens Reset Mode the MA dot2 Node4 will be reseted all settings w...

Page 39: ...e only with dry soft cloth Do not use any liquid cleaner or compressed air Do not use any solvent Check ventilation holes are clear Depending on the environment we recommend to clean the device profes...

Page 40: ...product Product category Control unit Name of product dot2 Node4 complies with the following product specifications and harmonized standards Safety EN60065 EN60950 1 LVD Low Voltage Directive 2014 35...

Page 41: ...e used for running programming or offline programming a show Furthermore it is expandable to a complete design studio by connecting it to dot2 3D And is a way to use the dot 2 Node4 as real light cons...

Page 42: ...technology and some specialties e g Touch Command Screen the dot2 series is particularly suitable for small and medium sized projects in the light scene All command buttons have within the dot2 serie...

Page 43: ...42 Ger tetyp model dot2 Node4 Optionen options Seriennummer serial number Baujahr year of manufacture Distributor dot2 Node4...

Page 44: ...dot2 Node4 Notizen notes...

Page 45: ...47x...

Reviews: