background image

 

  MA 8Port Node

 

 

Data 

 

Transport 

 

Safety 

instructions 

 

Safety and 

environmet 

 

Quickstart  

Connect 

 

Quickstart  

ON / OFF 

 

Maintenance 

 

Conformity 

 

 

37 

Display 

After switching on this menu is displayed: 

 

 

 

 

 

 

 

 

 

 

 

 

Hold button MENU as long until the desired menu appears. Release the button when in a menu adjustment is to 
be made. To change the setting, press the button briefly, the new setting is color-coded. After a short time display 
returns to the above menu. 

 

Select Mode:  
Use the MENU-button to select NONE, MANET 2 or ARTNET. 
 

 
 
 
 
 

Info Mode: no settings possible 

 
 
 
 

Identify Mode: identifies this MA 8Port Node by flashing the respective  
configuration line in the console/onPC  
 
 
 
 
Reset Mode: the MA 8Port Node will be reseted, all settings will remain. 
 
 
Restore Mode: the MA 8Port Node will be reseted to Factory Default  
NOTE: after reset customize  IP -number. 

 

 

 

 

 

 

 

 

 

Summary of Contents for 8Port Node

Page 1: ...47x MA 8Port Node QuickMAnual Version XIII 01 deutsch english...

Page 2: ...M A LIGHTING...

Page 3: ...lle bersicht ein 2 TFT Display und vier Status LEDs Zus tzlich befindet sich ein USB Port f r einen optionalen Firmware Update per USB Stick Auf der Ger ter ckseite sind der Hauptschalter ein powerCON...

Page 4: ...tionen und detaillierte Manuals f r die onPC Software unter www malighting com Die h ufigst gestellten Fragen FAQ finden sie auf www malighting com oder schicken Sie uns eine E Mail mit Ihren Kontaktd...

Page 5: ...g Abmessungen 19 1HU 440mm x 190mm x 47mm 8 DMX OUT XLR 5 pin an der R ckseite Die DMX OUTs k nnen auch zu DMX IN konfiguriert werden Ethernet RJ 45 Netzwerk Anschluss USB Anschluss an der Front nur f...

Page 6: ...Erforderlicher Steckertyp Power In PowerCon blau von Fa NEUTRIK AG Liechtenstein Erforderlicher Steckertyp Power Out PowerCon grau von Fa NEUTRIK AG Liechtenstein ACHTUNG Die Gesamt Stromaufnahme der...

Page 7: ...nder verantwortlich bei Nichtbeachten k nnen Personen oder Sachsch den entstehen Verwenden Sie f r Lagerung und Transport eine sichernde und sch tzende Transportvorrichtung Stellen Sie die Ger te nich...

Page 8: ...Quickstart ON OFF Wartung Konformit t 07 Symbole und Warnzeichen I 0 Achtung Warnung vor einer Gefahrenstelle Achtung Warnung vor Gef hrlicher elektrischer Spannung Hauptschalter AN AUS Wechsel strom...

Page 9: ...uss Stellen Sie keine Gegenst nde auf das Netzkabel und achten Sie darauf dass niemand auf das Kabel treten kann Wird ein Verl ngerungskabel benutzt muss sichergestellt werden dass die Summe der Nennl...

Page 10: ...Wartung Konformit t 09 Warnhinweise Die Wartung des Ger tes darf ausschlie lich durch geschultes Personal durchgef hrt werden da beim ffnen und oder Entfernen von Abdeckungen spannungsf hrender Teile...

Page 11: ...F bis 122 F Luftfeuchte Betrieb 20 bis 80 relative Luftfeuchtigkeit keine Betauung Lagerung Transport 10 bis 80 relative Luftfeuchtigkeit keine Betauung Umgebung Bitte alle Sicherheitshinweise beachte...

Page 12: ...dem Standard des Einbauortes angepasst werden PowerCon Out grau Werden zus tzliche Ger te angeschlossen muss sichergestellt werden dass die Summe der Nennleistungen der an das Kabel angeschlossenen Ge...

Page 13: ...MA 8Port Node onPC MA 4Port Node onPC MA 2Port Node onPC sowie MA onPC command wing und MA onPC fader wing addieren in beliebiger Kombination Parameter bis zur maximalen Parameterzahl Rechenbeispiel 1...

Page 14: ...MA 8Port Node Daten Transport Sicherheit Betriebsgrenzen Quickstart Connect Quickstart ON OFF Wartung Konformit t 13 Montage Optionen Option f r die Montage im 19 Rack...

Page 15: ...ut z B 30 Frequenz des DMX Ausgangs in Hz max 30Hz sind m glich IP Adresse z B 192 168 0 116 Mode MANET2 oder ARTNET Nummer der Session z B Session 3 der MA 8PORT Node befindet sich in der Session 3 z...

Page 16: ...dr cken die neue Einstellung ist farbig gekennzeichnet Nach kurzer Zeit springt die Anzeige wieder auf das erste Men zur ck Select Mode Mit dem MENU Button NONE MANET 2 oder ARTNET einstellen Info Mod...

Page 17: ...ch erscheint die Anweisung Please press key for update recovery Jetzt die Men Taste dr cken Jetzt erscheint die Anweisung Please press key for FORMAT Gleichzeitig startet f r ein paar Sekunden ein Lau...

Page 18: ...t Node eine andere Version der Software geladen als die Konsole oder der onPC In diesem Fall m ssen die Software Versionen angepasst werden Einen USB Stick FAT 32 mit dem Installationsprogramm 8port_v...

Page 19: ...In der Konsole oder onPC das Men SETUP CONSOLE XYX SOFTWARE UPDATE ffnen Bei Bedarf die Firmware Version des MA 8Port Node angleichen falls das Feld Version rot unterlegt ist IP Adresse des MA 8Port N...

Page 20: ...und SAVE oder CANCEL Abbruch dr cken Laden der Konfiguration Das Men SETUP NETWORK MA NETWORK CONFIGURATION ffnen ein Ger t selektieren und den Button IMPORT CONFIGURATION dr cken Ein Laufwerk selekt...

Page 21: ...t es ratsam das Ger t alle 2 5 Jahre durch einen autorisierten Service reinigen zu lassen Wartung Das Ger t bedarf keiner regelm igen Wartung deshalb ist es auch nicht notwendig das Ger t zu ffnen Ach...

Page 22: ...16 D 97297 Waldb ttelbrunn Deutschland Erkl rt dass die Produkte Produktkategorie Kontrollger t Produktnamen MA 8Port Node Den folgenden Produktspezifikationen entspricht Sicherheit EN60065 EN60950 1...

Page 23: ...mieren am Laptop oder PC Mit der grandMA 3D Software kann es zum perfekten Designstudio erg nzt werden und es ist die Grundlage f r die Funktion des MA 8Port Node Die grandMA2 onPC und grandMA 3D Soft...

Page 24: ...en in der Licht Szene ger stet Au erdem bietet das neu entwickelte faderwing bis zu 60 zus tzliche Executor Fader Und die grandMA2 full size kann die showfiles der Serie 1 in einem speziellen Serie1 M...

Page 25: ...onally there is a USB port for optionally update of firmware vis USB stick The mains switch is located on the back along with the powerCON and etherCON connectors as well as eight DMX ports The MA 8Po...

Page 26: ...ee www malighting com Please check our Frequently Asked Questions first that you can find online at www malighting com If there are any questions left just send us an e mail with your contact details...

Page 27: ...abel and connector not included ex works Socket type Power In PowerCon blue by NEUTRIK AG Liechtenstein Socket type Power Out PowerCon grey by NEUTRIK AG Liechtenstein ATTENTION The total current powe...

Page 28: ...Dimensions 19 1HU 440mm x 190mm x 47mm 17 3 inch x 7 5 inch x 1 8 inch 8 DMX OUT XLR 5 pin on the rear side Each DMX OUT can be individually configured as DMX IN Ethernet RJ 45 network connector USB P...

Page 29: ...observing the safety regulations of the manufacturer when using means of transport Non compliance can result in personal injury or material damage Use protective transport device for transport and sto...

Page 30: ...nmet Quickstart Connect Quickstart ON OFF Maintenance Conformity 29 Symbols and warning labels I 0 Warning Danger Area Warning Danger of electric shock Supply voltage ON OFF Alternating current AC Dis...

Page 31: ...s provided with a safety plug This plug can only be used with safety sockets These precautions should by all means be followed If the plug should not fit into a given socket e g the case with old sock...

Page 32: ...start Connect Quickstart ON OFF Maintenance Conformity 31 Electric shock warning The unit should be serviced by qualified personnel only as live parts may be exposed when opening and or removing cover...

Page 33: ...sport 10 C up to 50 C 14 F up to 122 F Humidity Operation 20 up to 80 relative humidity no condensation Storage Transport 10 up to 80 relative humidity no condensation Environment Follow all the IMPOR...

Page 34: ...en end must be fitted with a shock proof plug and must meet the local requirements PowerCon Out grey ATTENTION The total current power consumption of the units connected in series must not exceed the...

Page 35: ...ers There are just two simple rules that need to be followed First rule The maximum parameter count with grandMA2 onPC is 4 096 parameters Second rule In any combination MA 8Port Nodes onPC MA 4Port N...

Page 36: ...MA 8Port Node Data Transport Safety instructions Safety and environmet Quickstart Connect Quickstart ON OFF Maintenance Conformity 35 Installation Options for 19 rack mounting...

Page 37: ...of MA 8Port Node e g support8Node DMX Output e g 30 frequency of DMX output in Hz max 30Hz possible IP Address e g 192 168 0 116 Mode MANET2 or ARTNET Number of Session e g Session 3 MA 8Port Node is...

Page 38: ...ange the setting press the button briefly the new setting is color coded After a short time display returns to the above menu Select Mode Use the MENU button to select NONE MANET 2 or ARTNET Info Mode...

Page 39: ...following instruction appears Please press key for update recovery press button MENU now Now following instruction appears Please press key for FORMAT Simultaneously for an few seconds a loading bar...

Page 40: ...PC i e the first 3 IP address groups must be identical If the cell Firmware has red letters the 8Port Node runs a software version different from that of the console or onPC In this case you have to a...

Page 41: ...ll only show the most important settings For configuring a node you have to use a grandMA console or the onPC software Open menu SETUP CONSOLE XYX SOFTWARE UPDATE at the console or onPC If necessary u...

Page 42: ...SB flash drive Type file name and press SAVE or CANCEL abort Load Configuration settings Open menu SETUP NETWORK MA NETWORK CONFIGURATION select device and press button IMPORT CONFIGURATION Select dri...

Page 43: ...surface only with dry soft cloth Do not use any liquid cleaner or compressed air Do not use any solvent Check ventilation holes are clear Depending on the environment we recommend to clean the device...

Page 44: ...hdeckerstra e 16 D 97297 Waldb ttelbrunn Germany declares that the product Product category Control unit Name of product MA 8Port Node complies with the following product specifications Safety EN60065...

Page 45: ...be used for running programming or offline programming a show Furthermore it is expandable to a complete design studio by connecting it to grandMA 3D and it s the basis for the function of the MA 8Po...

Page 46: ...ghting segments Intuitive and fast control over all connected fixtures and channels in different styles is self evident Furthermore the newly developed faderwing provides in addition up to 60 executor...

Page 47: ...46 Ger tetyp model MA 8Port Node Optionen options Seriennummer serial number Baujahr year of manufacture Distributor...

Page 48: ...47 Notizen notes...

Page 49: ...ine Haftung bei Fehlern oder Ungenauigkeiten in diesem Booklet Without having any written permission from MA Lighting Technology GmbH it is not allowed to copy reproduce or publish any part of this bo...