Chapter 7. Device operating and settings. 

 

7.1 Base screen 

 
 
 
 
 
 
 
 
7.1.1 The status bar provides the device's mode status, communication mode and battery status. 
 

Icon 

Description 

SCAN 

Successful reading of the data code is indicated with the data value. 

DATA 

Displayed when managing internal memory data. 

 

Indicates that the device is connected in IrDA communication mode. 

 

Indicates that the device is connected in USB communication mode. 

 

Indicates that the device is connected in RF communication mode. 

 

Indicates the internal battery level. If the battery is low, a low voltage warning message is 
generated and the power is automatically turned off. 

 
7.1.2  Show  system  notifications  displays  a  notification  window  from  which  you  can  choose  to  manage  and 
control your device. 
 

Text 

Description 

READY 

Indicates that the device is operating normally. 

SCAN OK 

Indicates that reading the data code was successful. 

SEND? 

Confirm that you want to send the selected data. When pressed again, it is sent. 

SEND ALL? 

Confirm that you want to transfer all data stored on the device. When pressed again, it is 
sent. 

SEND OK 

Indicates that the transfer of data stored on the device was successful. 

ERASED? 

Confirm that you want to delete the selected data. Press again to delete. 

ERASED ALL? 

Confirm that you want to delete all data stored on the device. Press again to delete. 

EMPTY 

Indicates that data stored on the device does not exist. 

TOTAL [    ] 

Displays the number of data currently stored in the internal memory. 

 
 
 
 

Summary of Contents for UDJET MSR-B2MWA

Page 1: ......

Page 2: ...ng si Gyeonggi do 14055 Republic of Korea 2 17 Thank you for purchasing the industrial Barcode reader of M2I corporation Please read this manual carefully to know installing operating this equipment f...

Page 3: ...Names and General Specifications 7 4 1 MSR B2MWA and MSR B2MWA DONGLE 7 4 2 Part Names and Specifications 8 Chapter 5 Interface 9 5 1 USB 9 5 2 RF Wireless Communication 9 5 3 IrDA 9 Chapter 6 Instal...

Page 4: ...ter liquids or metal powders to enter into the front screen protective sheet The screen may be invisible or may cause a malfunction of the touch Use the radio or mobile phone at least 30cm away from t...

Page 5: ...r is an industrial control device required in industrial field It is a device that is used for basic purposes to communicate with other devices PC HMI etc using high durability and wired wireless comm...

Page 6: ...l Memory 512KB 3 3 functional Specifications Barcode Scanner Sensor resolution Scan type 640 H x 400 V 1D 2D CMOS Barcode Data storage internal memory 32 768 Code GTIN 08 EAN 8 24 966 Code GTIN 13 EAN...

Page 7: ...product per IEC EN 62471 Protection Classification Product body IP67 3 6 Structure Specifications Weight g MSR B2MWA MSR B2MWA DONGLE 180 3 Cooling System Natural air circulation Case Material PC Flam...

Page 8: ...IrDA OLED 1 3 OLED Display Power LED Display the System Power State UP Switch UP Switch SEND Switch SEND Switch Charge status indicator Red Charging OFF Charged DOWN Switch DOWN Switch SCAN Switch SCA...

Page 9: ...USB 1 1 compatible Communication Method Control Bulk Transfer Speed Max 12Mb s Connector Type Type C 5 2 RF Wireless Communication Dedicated wireless dongle required Model Name MSR B2MWA DONGLE Form...

Page 10: ...f main body and charging cable 3 Where the body and dongle are open 4 Out of direct sunlight 6 2 Battery Charging Connect the bottom of the terminal to the USB cable USB C Type 6 3 Dongle Installation...

Page 11: ...age warning message is generated and the power is automatically turned off 7 1 2 Show system notifications displays a notification window from which you can choose to manage and control your device Te...

Page 12: ...on to activate the scan mode If the barcode is successfully read the scan mode will automatically end with a buzzer sound and the read data value will be displayed on the screen Activated while the bu...

Page 13: ...ta Matrix 0 508 mm 3 8 cm 34 3 cm QR Code 0 508 mm 3 8 cm 27 9 cm 7 2 3 Checking Stored Data Press the UP DOWN button to check the saved data The total number of stored data the order of saving and th...

Page 14: ...nggi do 14055 Republic of Korea 14 17 Send OK is displayed upon successful transmission Data transmission supports 3 modes and connection priority is as follows The connection priority cannot be chang...

Page 15: ...te the saved data by pressing the ERASE button 1 You can select and delete the data saved internally with UP and DOWN button 2 When pressed ERASE A confirmation window will appear Press again to delet...

Page 16: ...lfunction of this equipment 3 If the problem cannot be solved at the installation site the equipment can be collected and moved to M2I Corporation 4 The manufacturer M2I Corporation is not responsible...

Page 17: ...I Corporation 11 35 Simin daero 327beon gil Dongan gu Anyang si Gyeonggi do 14055 Republic of Korea Device type Industrial Barcode reader Model MSR B2MWA DONGLE Operating Temperature 10 Ta 50 Power Sp...

Reviews: