M2I TOPRHWS Hardware Manual Download Page 11

TOPRHWS Hardware Manual 

     

M

2

I Corporation 

11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055,Republic of Korea

 

 

11 / 19 

PIN NO. 

SIGNAL. NAME 

Description 

Pair Line 

COMM_0 

COM1 or Ethernet SEL #1 

PAIR1(+) 

VCC_IN 

TOPRH Power IN 24V 

PAIR3(+) 

COMM_1 

COM1 or Ethernet SEL #2 

PAIR1(-) 

VCC_IN 

TOPRH Power IN 24V 

PAIR4(+) 

COMM_2 

COM1 or Ethernet SEL #3 

PAIR2(+) 

PGND 

TOPRH Power GND 

PAIR3(-) 

COMM_3 

COM1 or Ethernet SEL #4 

PAIR2(-) 

PGND 

TOPRH Power GND 

PAIR4(-) 

NC 

   

10 

NC 

   

11 

NC 

   

12 

NC 

   

13 

COMM_9 

EMG A1_com 

PAIR5(+) 

14 

COMM_8 

EMG A1 contact 

PAIR5(-) 

15 

EXT0_EMG_B1 

EMG B1_com 

PAIR6(+) 

16 

EXT0_EMG_A1 

EMG B1 contact 

PAIR6(-) 

17 

COMM_13 

EMG B2_com 

PAIR7(+) 

18 

COMM_12 

EMG B2 contact 

PAIR7(-) 

19 

3P_SW_A0_COM 

3Position Switch A_com 

PAIR8(+) 

20 

3P_SW_A0 

3Position Switch A_contact 

PAIR8(-) 

21 

3P_SW_A2_COM 

3Position Switch A2_com 

PAIR9(+) 

22 

3P_SW_A2 

3Position Switch A2_contact 

PAIR9(-) 

23 

NC 

   

24 

COM_SG 

COM1 Signal GND 

25 

NC 

   

26 

NC 

   

 
 
 
 
 

  Connector #2: Yeonho Electronics SMH200-12C, Cable 26AWG 
 

PIN NO. 

SIGNAL. NAME 

Description 

Pair Line 

KEY0_A 

KEYLOCK 

KEY0_COM 

KEYLOCK_COM 

PAIR14(-) 

NC 

   

NC 

   

NC 

   

COM0 

FUNCTION_COM 

PAIR10(-) 

DOUT5 

FUNCTION_6 

DOUT4 

FUNCTION_5 

PAIR11(-) 

DOUT3 

FUNCTION_4 

Summary of Contents for TOPRHWS

Page 1: ...gan gu Anyang si Gyeonggi do 14055 Republic of Korea 1 19 Thank you for purchasing M2I TOPRHWS Please read this user manual carefully for safe installation wiring and operation of this equipment befor...

Page 2: ...Serial Communication Specifications 7 5 2 Ethernet Communication Specifications 8 Chapter 6 Block Diagram for Installation 9 6 1 Connection Diagram 9 6 2 Panel Cut Size for Front Panel Installation 1...

Page 3: ...store or operate in an environment exposed to sunlight Do not touch an adaptor or power code with wet hands It can cause electric shock Do not use this product in explosive environments with flammabl...

Page 4: ...erminal screw with the specified torque The loose screws of the terminal can be the cause of short circuit a fire or and malfunction Use a standard earthing for FG terminal When not earthed it can cau...

Page 5: ...she operates and monitors an installation system 2 2 Components The components of the product are as follows Before use please check that all of the following components are included Item Picture Quan...

Page 6: ...Pulse width 1 Static Electricity Discharge Connective discharge from EN61000 4 2 4 Shock Endurance 10G X Y Z each direction for 3 times Surge Voltage 500V Line Line Ground Connection Class 3 100 under...

Page 7: ...About 15m Type of connection 1 1 Control code ASCII Code or HEXA Code Baud rate 2400 4800 9600 19200 38400 57600 76800 115200 bps Data type Data Bit 7 8 bit Parity Bit NONE ODD EVEN Parity Stop Bit 1...

Page 8: ...ations 5 2 1 Ethernet Item Specification Ethernet Method IEEE802 3i IEEE802 3u 10BaseT 100BaseT Speed 10M 100Mbps Communication Method Base Band Switching Method AUTO MDIX Maximum Segment Length 100m...

Page 9: ...xposing the front and the other is fixing it to DIN Rail of the rear TOPRHWS is connected to TOPRH0700WD FE with predefined 26 fin cable 6 1 Connection Diagram TOPRHWS should be connected with the mai...

Page 10: ...anel Cut Size for Front Panel Installation Please refer to below drawings for front panel installation TOPRHWS TOPRHWS02 6 3 Cable Diagram Please check part information of TOPRH0700WD FE connecting ca...

Page 11: ...EMG A1_com PAIR5 14 COMM_8 EMG A1 contact PAIR5 15 EXT0_EMG_B1 EMG B1_com PAIR6 16 EXT0_EMG_A1 EMG B1 contact PAIR6 17 COMM_13 EMG B2_com PAIR7 18 COMM_12 EMG B2 contact PAIR7 19 3P_SW_A0_COM 3Positi...

Page 12: ...6 A6 EMG A1 contact PAIR5 Emergency_A1 Out 7 A7 EMG B1_com PAIR6 Emergency_B1 com 8 A8 EMG B1 contact PAIR6 Emergency_B1 Out 9 B1 EMG B2_com PAIR7 Emergency_B2 com 10 B2 EMG B2 contact PAIR7 Emergency...

Page 13: ...RH0700WD FE and TOPRHWS should be identical 1 It can be set for Serial or Ethernet communication 2 When using serial communication mode it is possible to use RS 232C 422 485 When Ethernet is selected...

Page 14: ...s wired as follows Position EMG_A1 EMG_B1 EMG_B2 Not Pressed Open OFF Short ON Short ON Pressed Short ON Open OFF Open OFF It is a mechanical switch which can operate regardless on off status of main...

Page 15: ...ditionally controls the controllability of the controller A source type function key cannot be used Signal Fn Dout 0 F1 Dout 1 F2 Dout 2 F3 Dout 3 F4 Dout 4 F5 Dout 5 F6 Dout_com It runs with a photoc...

Page 16: ...troller Position 3P_SW_A0 3P_SW_A2 NOT Pressed Open OFF Open OFF HALF Pressed Short ON Short ON Fully Pressed Open OFF Open OFF It is a mechanical switch which can operate regardless on off status of...

Page 17: ...When installing the power plug use a pin terminal to improve the coupling of power wire and electrical transmission Attach the power cable to the power terminal of the equipment as below 1 Below are t...

Page 18: ...wer a Is the input voltage range 3 Related Items a Check the touch pad there is no damage scratch or pollution 8 3 Problems with the Product 1 When a problem occurs during operation stop using the pro...

Page 19: ...Temperature 10 Ta 50 Power Specifications TOPRHWS 24Vdc 20W or less TOPRHWS02 24Vdc 20W or less KC Certificate No Product No Copyright M2I corporation 2022 08 www m2i co kr When using M2I equipment r...

Reviews: