background image

3. The factory default parameters are temperature: 40°C, vacuum time:
45 seconds, bonding time: 45 seconds, and defoaming time: 10 minutes.

*No special requirements, please do not adjust the parameters without

authorization, if you need to change the parameters, please contact the
manufacturer after sales.

(2).Pressure screen and matters needing attention

1. Use the screen positioning mold to carry out preliminary positioning and

bonding of the liquid crystal and the cover plate.

*Note that after the cover and the LCD are closed, do not squeeze or press.

Usually there will be a hollow in the middle of the bottom of the mold. Just

press and hold the middle of the cover with your fingers, and then tap the

LCD in the middle of the bottom of the mold to make the middle stick That's

right, this is extremely important!

Summary of Contents for MT-18

Page 1: ...MT 18 air bag all in one machine User Manual 1 Safety Rules 2 Specifications 3 Steps for usage 4 Devices Care...

Page 2: ...damage or endanger personal safety C Non professionals are strictly forbidden to open the electric box 2 Specifications Equipment power supply AC250V optional AC110V AC220V Working environment 20 30...

Page 3: ...2 Press Parameter Setting to set device parameters 0 0 40 0...

Page 4: ...sure screen and matters needing attention 1 Use the screen positioning mold to carry out preliminary positioning and bonding of the liquid crystal and the cover plate Note that after the cover and the...

Page 5: ...is very important which directly affects the final yield The edge of the display window of the screen should be aligned with the edge of the sponge pad so as to completely avoid the cable Pressure le...

Page 6: ...ng The higher the altitude the lower the peak value of negative pressure and the best effect is when the negative pressure is above 88 5 Usually the air in the cabin can be pumped out within 45 second...

Page 7: ...values on the display screen The door can only be opened when the air pressure is zero 3 Working mode 1 Laminating mode Press the start button the device can start to work the machine starts to vacuu...

Page 8: ...when the set defoaming time is reached the device starts to deflate the positive pressure value returns to zero and the defoaming is completed Observe the pressure gauge during the defoaming process n...

Page 9: ...fit and defoaming are completed The defoaming time can be adjusted according to the size of the bubbles on the screen at least 5 to 10 minutes 4 Equipment maintenance Maintenance item Precautions for...