3. The factory default parameters are temperature: 40°C, vacuum time:
45 seconds, bonding time: 45 seconds, and defoaming time: 10 minutes.
*No special requirements, please do not adjust the parameters without
authorization, if you need to change the parameters, please contact the
manufacturer after sales.
(2).Pressure screen and matters needing attention
1. Use the screen positioning mold to carry out preliminary positioning and
bonding of the liquid crystal and the cover plate.
*Note that after the cover and the LCD are closed, do not squeeze or press.
Usually there will be a hollow in the middle of the bottom of the mold. Just
press and hold the middle of the cover with your fingers, and then tap the
LCD in the middle of the bottom of the mold to make the middle stick That's
right, this is extremely important!