5. Safety Precaution (in use)

1)Use a properly grounded electrical outlet of correct voltage and current handling capacity. This unit 
operates only by AC200-230V  50/60㎐ without danger. Check supplied voltage and current of AC200-230V,
 50/60HZ before use.  
2)Do not cover top plate with aluminum foil to prevent overheating, or fatal damage may result.
3)Keep the controller out of fluid.
4)Keep the unit out of particle and fluid. Inflow of particle and fluid into the unit can be a cause of fire.
If inflow of paricle or liquid, remove them after turn your power swich off and disconnect the plug
5)Do not put a strain on unit,it can be damaged.
6)Hot surface on operation. Avoid contact.
7)Do not drop objects onto your unit and do not drop your unit.
8)Turn your power switch OFF and disconnect the plug whenever you leave the unit.
9)Power cable should not be contacted hot plate.

etc.

4)Contirm carfully  the plug connected correctly. Wrong connection of  the plug may cause fire.
5)Do not leave the unit whenever the unit is on running.Turn your power switch OFF whenever the item is
 not used, or before disconnecting the plug.
6)Do not use the unit on other purpose.
7)Hot surface. Avoid contact. The hot plate will remain hot without any visual indication on power as well 
after power has been removed for sometime .

6. Operation and control

1)Turn volume switch OFF and check the voltage(AC200-230V 50/60㎐) before plugging in. And connect 
the power cord (6) to power supply(AC200-230V 50/60㎐).
2)Place your container or heating bath with the magnetic stirrer bar. Stirrer bar should be placed in center
of hotpate.
3)Turn main power S/W(5) ON.
4)Heating : Use heater control (1) to adjust hot plate temperature.

(LED (2) confirms heating current ON.)

The below chart shows the surface temperature chart of hot plate on the position of volume scale.
1. Each data was measured without vessel or container after instrument starts for 30 Min. 

2. Input power : AC200-230V 50/60㎐

3. Ambient temp. :40℃

4.Tolerance :  /- 5 %

5. These data can be changed as per the different conditions.

5)Stirring: Use motor control volume (4) to adjust motor speed rpm.

(Analog Type:Turn the speed control(4) ON.  A  LED (3) confirms the current ON.Set speed
to meet your needs by rotation of the speed control (4) on the front panel.

6)Do not place anything on top plate when use finishes.
7)Turn the main power S/W OFF.
8)Turn your power switch OFF and disconnect the plug whenever the unit is not in use. 
   Keep the unit clean.

Note:
1)Range of speed control : 100~1500 rpm
  (Every 10rpm increases by rotation the knob right-handed and every 10rpm decreases by rotation the
 knob left-handed)
2)Speed control knob in extreme left (CCW) position stops operating.
3)Set the speed(rpm) with the dial,it arrives at the set value shortly and maintaind contant speed by
  arithmetic logic unit.(Smooth start function)
4)If motor does not run on starting,make it run in 3 second by a increasing or output until 10rpm
   or more.

Warning

Warning

Note

Note

Unsuitable use causes danger !

Danger

3)Some parts of this product have limited life span,and others are changed by their usage.

1)If you use the product with methods other than specified by the manufacturer,there may be bodily injuries or
property damages.

Unsuitable use causes danger !

2)When the product gets wet,the inspection is essential because there is danger of an electric leakage or fire.

!

 

!

 

!

 

!

 

!

 

www.mtops.co.kr

[email protected]

MISUNG  SCIENTIFIC  CO

Summary of Contents for MS100

Page 1: ...lic of Korea MISUNG SCIENTIFIC CO LTD 89 Kwansu dong Chongro ku seoul 110 420 Republic of korea TEL 82 31 866 3808 FAX 82 31 866 3810 HEAD OFFICE FACTORY INSTRUCTION MANUAL MODEL MS100 HP100 MS200 MS300HS Hot plate Magnetic Stirrer Hot Plate Magnetic Stirrer www mtops co kr misung mtops co kr MISUNG SCIENTIFIC CO ...

Page 2: ...5 5 6 6 Operation and control We appreciate you for purchasing MISUNG SCIENTIFIC CO Ltd product Before using the product you have purchased check to make sure that it is exactly what you ordered Then please use it following the instructions below 1 Safety information 3 4 Explanation of each part 4 www mtops co kr misung mtops co kr MISUNG SCIENTIFIC CO ...

Page 3: ...condensation WARNING Touching the reactor block surfaces and vials while hot can cause serious burns This product requires a protective earth connection If not provided with a plug on a cord connect positive earth to this terminal 1 Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation 5 If there is a concern about a serious accidrnt cause...

Page 4: ...RER 5 Misung designed the unit which starts and stops smoothly to prevent fluid spillover from rapid turnover and detaching of stirrer bar 1 Ceramic coated stainless top plate Ceramic coated stainless top plate is corrosion proof Your Misung hot plate stirrer or stirring hot plate is a general purpose heating and or stirring plate designed for labolatory procedures requiring precise control of tem...

Page 5: ...ain power S W 5 ON 4 Heating Use heater control 1 to adjust hot plate temperature LED 2 confirms heating current ON The below chart shows the surface temperature chart of hot plate on the position of volume scale 1 Each data was measured without vessel or container after instrument starts for 30 Min 2 Input power AC200 230V 50 60 3 Ambient temp 40 4 Tolerance within 5 5 These data can be changed a...

Page 6: ...fuse In case of a malfunction as described above contact your authorized Misung Dealer 9 SPECIFICATIONS Plate area AC 230 220V 50 60 DIMEN SIONS 250V T1AH 250V T5AH Fuse Weight Overall WxDxH Power HOT PLATE HOT PLATE STIRRER MAGNETIC STIRRER 180 x 180mm 100 1500rpm Up to 5000mL Feed back control H E A T E R Capacity Temperature range Control Ceramic coated top plate Up to 380 680W Proportion contr...

Reviews: