M-Therm HT-08 Installation Manual Download Page 2

Digital Thermostat 

M

-Therm HT- 08 

For 

M

-Therm 24 Volts heating systems  

 

 

2 / 2 

 
 

Enter weekly program 

The  programming  of  the  thermostat  is  based  on  a  7-day/24-hour  weekly  program  which  can  be  set  according  to  personal 
preferences.  The  factory  setting  for  comfort  time  is  from  6  a.m.  to  10  p.m.  You  can  now  change  these  settings  according  to  your 
personal wishes. 
 
7.1  Turn the rotary switch to the respective weekday. 
7.2  You can set every half hour of the day by means of the keys (+) and (-). The clock indicates the time you are programming. 
7.3  Press the sun-key (for comfort temperature) or the moon-key (for lowered night temperature) to change the day or night setting. 

For your guidance, the symbols you are currently working on are blinking in the display. 

7.4  After having terminated the programming of all weekdays, set the rotary switch back to (RUN) and the thermostat will start to 

operate its program. 

 

Manual and temporary room temperature change without influencing the scheduled weekly programming 

You  can  override  the  programmed  room  temperature  if  it  is  too  cold  or  too  warm  at  a  specific  moment.  This  override  mode  is 
temporary and valid only until the next programmed change from (moon) to (sun) or vice versa. 
8.1  Set the rotary switch to the position (RUN). 
8.2  Press the key (+) or (-) and the current temperature setting will be displayed. 
8.3  Press again the keys (+) or (-) to change the current temperature setting. 
8.4  The  display  will  be  flashing  for  approx.  8  seconds  and  then  returns  to  the  main  menu.  The  thermostat  will  start  with  the 

temporarily set temperature until the next programmed change (from sun to moon or vice versa). 

8.5  Turn the switch shortly away from (RUN) and immediately back again to (Run) to terminate the manual override and to return to 

the scheduled programs. 

 

Holiday mode 

The automatic thermostat program can be permanently interrupted in order to set a constant temperature for an arbitrary period, for 
instance during your holidays. 
9.1  Set the rotary switch to the position (RUN). 
9.2  Press the key (HOLD). The display shows "Temp Set“ and "Hold“. 
9.3  Set the desired temperature with the keys (+) and (-). 
9.4  After having terminated the temperature setting, the display continues flashing for approx. 8 seconds and then switches back to 

the display of the ambient temperature. The „Hold“-temperature (temporary temperature) is not displayed. The thermostat will 
start running the "holiday"-mode. 

9.5  Turn the switch shortly away from (RUN) and immediately back again to (Run) to terminate the „Hold“-function and to return to 

the scheduled programs. 

 
 
10  Problem solving 

 

Problem 

Possible cause 

Elimination of the cause 

LED on the transformer shows a 
permanent red light (heating 
system out of operation) 

Floor sensor (or resistance for the wall 
heating) not or badly connected to the heating 
control 

Connect floor sensor (or resistance for the 
wall heating) correctly (see heating control 
manual) 

LED on the heating control 
keeps blinking red  
(heating system out of 
operation) 

Device is overheating due to trapped heat 

Elimination of erroneous obstruction of the 
heating control 

Device is overheating due to exterior heat 
effects 

Eliminate external heat effects due to 
intensive solar radiation or other heat 
sources (other devices) 

System out of operation (LED 
off) 

Heating control switched off 

Switch on the power on the device 

Temperature selection on the room thermostat 
too low 

Set correct temperature on the room 
thermostat 

Overstrain of electrical circuit has blown main 
fuse  

Elimination of circuit overstrain. Disconnect 
some devices on the same fuse. Switch on 
main fuse 

Fuse of the device has blown 
 

Switch off the control unit. Replace fuse of 
the device by a new one of the same type. If 
the new fuse blows again after switching the 
device on, consult an electrician or the 
technical service of your sales point.  

Individual heating elements do 
not heat up 

Overstrain in individual heating circuits has 
blown heating circuit fuse(s). 

Elimination of overstrain of the heating circuit 
(not more than 2 heating panels per heating 
circuit allowed). Then replace heating circuit 
fuse.  

Individual heating panels or heating circuits 
are not connected 

Set up correct electrical connections of the 
heating circuits. 

Heating does not switch on or off 

Batteries in the thermostat are empty 

Replace batteries 

 