COMPONENT IDENTIFICATION

• Range

Same range for all channels.  Use PC Configurator to set 
independent ranges per channel.

OUTPUT RANGE

SW2-1

0 − 20 mA DC

OFF

4 − 20 mA DC (*)

ON

• Output at The Loss of Communication

Same output for all channels.

OUTPUT AT THE LOSS OF COMMUNICATION

SW2-5

Output Hold (*)

(last data correctly rerceived is hold)

OFF

Stop output 

ON

[Note] For Stop output, output fixed at -5%, 0 mA min. when 

configuration mode is DIP switch setting.
Output fixed at scaling value at the loss of communication 
when configuration mode is PC.

• Terminator DIP SW

TERMINATOR SW

SW2-6

Without (*)

OFF

With

ON

• Configuration Mode

CONFIGURATION MODE

SW2-8

DIP switch setting (*)

OFF

PC Configurator and communication

ON

[Note] Be sure to set unused SW2-2 through 2-4 and 2-7 to 
OFF.

 PC CONFIGURATOR

The following parameters can be set with using PC Configu-

rator Software (model: R8CFG):
• Output setting by channels (range, scaling, zero/gain ad

-

justments, scaling value at power on, slaling value at the 

loss of communication)

• Common setting (loss of internal bus communication de

-

tection time)

Turn SW2-8 ON to allow programming by the PC Configu

-

rator via the Power/Network Module.
Refer to the users manual for the R8CFG for detailed opera

-

tion of the software program.

 INDICATOR LED

LED

OPERATION

FUNCTION

Status

OFF

Stopping

Green ON

Valid host communication

Green Blinking

Reading/writing configuration

Red ON

Setting error

Red Blinking

Parameter error

Output

Status

OFF

Output data in the range

Red Blinking

Output data out of range

 OUTPUT CONNECTOR ASSIGNMENT

  PIN 

ID 

FUNCTION

  No.
  1 

Output (+)

  2 

NC 

No connection

  3 

NC 

No connection

  4 

− 

Output (−)

1

2

3

4

 OPERATING MODE

(*) Factory setting

• Module Address

The  SW1-1,  SW1-2,  SW1-3,  SW1-4  determines  the  tenth 
place digit, while the SW1-5, SW1-6, SW1-7, SW1-8 does the 

ones place digit of the address.

Address is selected between 0 to 31.
(Factory setting: 0)

MODULE ADDRESS

SW1

×10

1

2

3

4

×1

5

6

7

8

0

OFF

OFF

OFF

OFF

1

OFF

OFF

OFF

ON

2

OFF

OFF

ON

OFF

3

OFF

OFF

ON

ON

4

OFF

ON

OFF

OFF

5

OFF

ON

OFF

ON

6

OFF

ON

ON

OFF

7

OFF

ON

ON

ON

8

ON

OFF

OFF

OFF

9

ON

OFF

OFF

ON

AO_I2

AO_I1

8

7

6

5

4

3

2

1

SW1

SW2

On

RUN

Status Indicator LED

Output Status Indicator LED

Internal Bus Connector

Output Connector 1

Output Connector 2

Function Setting

DIP SW

■ 

FRONT VIEW

■ 

SIDE VIEW

Summary of Contents for R8-YS2

Page 1: ...NERAL PRECAUTIONS Before you remove or mount the unit turn off the power supply and output signal for safety Switches on the side of the module can be set for mainte nance only while the power supply is off Do not access them while the power is supplied ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ven tilati...

Page 2: ...de it straight until the hooks are latched Groove Hook When removing the cover pull it out while squeezing the hooks inward HOW TO UNMOUNT THE MODULE ON DIN RAIL Removing an intermediate module Caution 1 Be careful not to hurt your hand by pointed edges of the internal communication bus connector 2 I O modules cannot hold tightly on the DIN rail by themselves without power network module Secure th...

Page 3: ... value at the loss of communication Common setting loss of internal bus communication de tection time Turn SW2 8 ON to allow programming by the PC Configu rator via the Power Network Module Refer to the users manual for the R8CFG for detailed opera tion of the software program INDICATOR LED LED OPERATION FUNCTION Status OFF Stopping Green ON Valid host communication Green Blinking Reading writing ...

Page 4: ...2 17 6 24 7 28 6 24 7 28 NC NC OUTPUT 1 NC NC OUTPUT 2 1 2 4 3 1 2 4 3 OUTPUT CONNECTOR 1 INTERNAL POWER INTERNAL BUS EXC SUPPLY OUTPUT CONNECTOR 2 BUS CONNECTOR WIRING INSTRUCTIONS e CON connector PWB connector XN2D 1474 S002 Omron Recommended cable connector XN2A 1470 Omron 1 Applicable wire size 0 08 mm2 AWG28 0 5 mm2 AWG20 Outer sheath diameter max 1 5 dia 1 The cable connector is not included...

Reviews: