R7L-EC8A

P.  / 2

EM-7804-O

NPN TRANSISTOR OUTPUT EXTENSION MODULE, 8 points

(L

ON

W

ORKS

)

MODEL

R7L-EC8A

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Discrete output extension module ............................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 FUNCTIONAL BLOCK SETTING

• Functional blocks regarding the extension module are set 

by the basic module.  Refer to the instruction manual for 
the basic module for detailed information.

 GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within 0 to 55°C (32 

to 131°F) with relative humidity within 30 to 90% RH in 
order to ensure adequate life span and operation.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close  to  noise  sources  (relay  drive  cable,  high  frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying  complete  performance  described  in  the  data 
sheet.

COMPONENT IDENTIFICATION

0 1 2 3 4 5 6 7

Indicator LED

Output Terminals

7

8

6

9 10

2

3

1

4

5

 OUTPUT TERMINAL ASSIGNMENT

 INDICATOR LED

Used to show discrete output signal status.
     

Contact ON  : LED ON

     

Contact OFF  : LED OFF

6

+24V

7

Y1

8

Y3

1

0V

2

Y0

3

Y2

9

Y5

4

Y4

10

Y7

5

Y6

 

NO. 

ID 

FUNCTION 

NO. 

ID 

FUNCTION

  1 

0V 

0V (common) 

6  +24V  24V DC

  2 

Y0 

Output 0 

Y1 

Output 1

  3 

Y2 

Output 2 

Y3 

Output 3

  4 

Y4 

Output 4 

Y5 

Output 5

  5 

Y6 

Output 6 

10  Y7 

Output 7

CONNECTING THE EXTENSION MODULE

1)  Remove the extension connector cover located at the 

side of the basic module.

2)  Connect the extension module.

3)  Mount the combined module on a DIN rail.