R7K4DH-1-DAC32D
P. 1 / 5
EM-7796-H Rev.1
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
PNP DISCRETE INPUT & PNP TRANSISTOR OUTPUT
MODULE, 16 points each
(High-speed Link System, e-CON connector)
MODEL
R7K4DH-1-DAC32D
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■
PACKAGE INCLUDES:
Discrete I/O module ...................................................... (1)
Surface mounter slider ................................................. (2)
■
MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■
INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■
CONFORMITY WITH EU DIRECTIVE
• Use dual shielded cables (Shinko Seisen Industry Model
ZHY262 PBA) for the network. If it is not sufficient, use a
ferrite core (Kitagawa Industries Model GRFC-13) for the
network cable.
• The actual installation environments such as panel con
-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■
POWER INPUT RATING & OPERATIONAL RANGE
Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V DC ±10%, approx. 95mA
■
GENERAL PRECAUTIONS
Before you remove the unit or mount it, turn off the power
supply, input signal and output signal for safety.
■
ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■
WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■
AND ....
The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.
COMPONENT IDENTIFICATION
■
FRONT VIEW
O
N
1
2
3
4
5
6
7
8
SW1
TERM
ON
ON
PWR
+
-
-
+
FE
SNSR.EX
C
×10
×1
STATION ADD.
Power Run
HLS1
HLS2
Status Indicator LED
Station Address Setting Rotary SW
Power Supply / Sensor Exc. Connectors
I/O Connector
Discrete I/O Status Indicator LED
RJ-45 Modular Jack for HLS
Operating Mode Setting DIP SW (SW1)
Terminating Resistor SW