FRONT VIEW

4

5

6

7

1

2

3

10 11 12 13

2

3

4

1

15 16 17 18

7

8

9

6

14

5

PWR

SA1

×10

SA2

×1

LNK2

NS

LNK1

MS

LNK1

LNK2

CNFG.

Status Indicator LED

RJ-45 Modular Jack

IP Address Setting 

Rotary SW

PC Configurator Jack

Output Terminals

Power Supply Terminals

Discrete Output Status Indicator LED

 

STATUS INDICATOR LED

ID

STATUS

COLOR FUNCTION

PWR

ON

Green

The internal power is supplied 
normally.

MS

ON

Green

Operating in a normal condition

Blinking

Standby (needs commissioning)

ON

Red

Critical failure

Blinking

Minor failure

OFF

No power supplied

NS

ON

Green

Link on-line and connections in 
the established state

Blinking

Link on-line but no connections 
in the established state

ON

Red

Critical failure

Blinking

Minor failure

OFF

No power supplied

LNK1

ON

Green

LNK1 is established

LNK2

ON

Green

LNK2 is established

 

IP ADDRESS

Set host address (2-digit hexadecimal number) in IP ad-
dress, with rotary switches SA1 for the first digit and SA2 
for the second digit, or when using network address and 
Subnet mask with modification, set 00H with the rotary 
switches and then set the parameters with PC configurator 
software (model: R7CFG). (Range: 00H – FFH)
(Factory setting: 01H)

IP Address   Host Address MSD (x1)

IP Address   Host Address LSD (x10)

012

34

56

789

AB

C

DE

012

34

56

789

AB

C

DE

 

DISCRETE OUTPUT STATUS INDICATOR LED

Discrete output module displays the status of each output 
with an LED (green).
  Contact ON : LED ON
  Contact OFF : LED OFF

 

PC CONFIGURATOR JACK

The PC Configurator is used to set the following parameters 
for each channel.

• IP address setting

  - IP address: 192.168.0.1
  - Subnet mask: 255.255.255.0
  - Default gateway: 192.168.0.1

• Communication Cutoff Output Settings

  Output clear (Output OFF)
  Output hold (Previous normal reception data hold) (*)
For more information about the programming using the 
R7CFG, please refer to the R7CFG Users Manual.
(*) Factory setting

4

NC

5

6

7

1

2

3

NC

24V 0V

NC

NC

FE

1. 

NC

2. 

NC

3. 

FE

4. 

NC

5. 

NC

6. 

+24V

7. 

0V

-
-
Functional earth
-
-
Power supply (24V DC)
Power supply (0V)

 POWER SUPPLY TERMINAL ASSIGNMENT

 

OUTPUT TERMINAL ASSIGNMENTS

14

5

6

Y7

Y6

Y8

15

Y9

16

17

18

7

8

9

Y11 Y13 Y15

Y10 Y12

10

1

2

V+

V−

Y0

11

Y1

12

13

3

4

Y3

Y5

Y2

Y4

Y14

NO.

ID

FUNCTION NO.

ID

FUNCTION

1

V–

0V

10

V+  24V DC (Out. Common)

2

Y0

Output 0

11

Y1

Output 1

3

Y2

Output 2

12

Y3

Output 3

4

Y4

Output 4

13

Y5

Output 5

5

Y6

Output 6

14

Y7

Output 7

6

Y8

Output 8

15

Y9

Output 9

7

Y10 Output 10

16

Y11 Output 11

8

Y12 Output 12

17

Y13 Output 13

9

Y14 Output 14

18

Y15 Output 15