background image

R7F4DC-DC16A-H

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7767-N  P. 5 / 7

MOUNTING INSTRUCTIONS

 

DIN RAIL MOUNTING (PARALLEL)

• Mounting

A) Set the upper hook at the rear side of the unit on the DIN 

rail.

B) Push in the lower.

A

B

• Dismounting

A) Push down the DIN rail mounter slider with tip of a mi-

nus screwdriver.

B) Pull the lower of the unit.
C) Remove the upper hook of the unit from the DIN rail.

A

C

B

 

DIN RAIL MOUNTING (RIGHT ANGLE)

• Mounting

A) Insert the longer DIN rail mounter slider until it clicks 

twice, as shown below.

A

B) Set the upper hook at the rear side of the unit on the DIN 

rail.

C) Push in the lower.

B

C

Note: leave at least 10 mm (.39 in.) at the both side of the unit.

• Dismounting

A) Push down the DIN rail mounter slider with tip of a mi-

nus screwdriver.

B) Pull the lower of the unit.
C) Remove the upper hook of the unit from the DIN rail.

C

A

B

 

SURFACE MOUNTING

A) Insert the two DIN rail mounter sliders until it clicks 

once, as shown below.

A

A

B) Mount the unit with M4 screws referring the External 

Dimensions. (Torque: 1.4 N∙m)

Summary of Contents for R7F4DC-DC16A-H

Page 1: ...e power source input and output connected to the unit etc POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below...

Page 2: ...le is receiving 1 Run LED turns off when no command is received from the master device DISCRETE OUTPUT STATUS INDICATOR LED Green LED shows the output status ON LED ON OFF LED OFF STATION ADDRESS The...

Page 3: ...nt from the master ON OFF OFF OFF OFF Unable to receive data due to wire breakdown ON OFF ON OFF ON OFF Faulty Baud Rate and or Station Address setting OFF OFF OFF OFF OFF Power input removed or power...

Page 4: ...utput 0 4 Y8 Output 8 Y1 1 24V 24V DC Y9 1 24V 24V DC 2 NC Unused 2 NC Unused 3 NC Unused 3 NC Unused 4 Y1 Output 1 4 Y9 Output 9 Y2 1 24V 24V DC YA 1 24V 24V DC 2 NC Unused 2 NC Unused 3 NC Unused 3...

Page 5: ...from the DIN rail A C B DIN RAIL MOUNTING RIGHT ANGLE Mounting A Insert the longer DIN rail mounter slider until it clicks twice as shown below A B Set the upper hook at the rear side of the unit on t...

Page 6: ...4 138 5 43 50 1 97 5 20 3 12 DIN rail 35mm wide 4 16 2 4 3 17 dia 4 16 deep CONNECTION DIAGRAM Note In order to improve EMC performance bond the FE1 terminal to ground Caution FE1 terminal is NOT a pr...

Page 7: ...F RY n 0 0 Unused Interval timed Response X Refresh Data Y I O DATA DESCRIPTIONS DISCRETE OUTPUT 0 15 Output 0 Output 1 Output 2 Output 3 Output 15 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1...

Reviews: