TABLE FOR THE CHOICE OF THE INJECTORS -
Cat:
II
2L 3B/P
NL
TABLE FOR THE CHOICE OF THE INJECTORS -
Cat:
II
2H 3+
TABLE FOR THE CHOICE OF THE INJECTORS -
Cat:
II
2E+ 3+
FR BE
ES
A
IR VENT NECESSARY FOR GAS COMBUSTION
= (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Triple ring (TR)
7,00
G30/G31
30/30 mbar
G25
25 mbar
BURNERS
Nominal
Power
[Hs - kW]
Reduced
Power
[Hs - kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,30
50
72 (F1)
Semi-rapid (SR)
1,75
0,45
65
94 (Y)
Rapid (R)
3,00
0,75
85
121 (F2)
Triple ring (TR)
3,50
1,50
95
138 (F3)
G30/G31
28-30/37 mbar
G20
20 mbar
BURNERS
Nominal
Power
[Hs - kW]
Reduced
Power
[Hs - kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,30
50
72 (X)
Semi-rapid (SR)
1,75
0,45
65
97 (Z)
Rapid (R)
3,00
0,75
85
115 (Y)
Triple ring (TR)
3,50
1,50
95
135 (T)
G30/G31
28-30/37 mbar
G20/G25
20/25 mbar
BURNERS
Nominal
Power
[Hs - kW]
Reduced
Power
[Hs - kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,30
50
72 (X)
Semi-rapid (SR)
1,75
0,45
65
97 (Z)
Rapid (R)
3,00
0,75
85
115 (Y)
Triple ring (TR)
3,50
1,50
95
135 (T)
256