background image

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-5494-Y1  Rev.1  P. 1 / 3

INSTRUCTION MANUAL

INSTALLATION BASE

(16 positions, 

Yokogawa DCS VMx/PM1 card use (PS-40PE-D4T1-PN1) /

 M3.5 screw terminal)

MODEL

M8BS1-16Y1

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Installation base ..................................................................(1)
Ferrite core (Kitagawa Industries GRFC-10) ....................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• This equipment is suitable for use in a Pollution Degree 

2 environment and in Installation Category II, with the 
maximum operating voltage 300V.  Basic insulation is 
maintained between the input and output.  Prior to in-
stallation, check that the insulation class of this unit sat-
isfies the system requirements.

• The equipment must be mounted inside a panel.
• Altitude up to 2000 meters.
• The equipment must be installed such that appropriate 

clearance and creepage distances are maintained to con-
form to CE requirements.  Failure to observe these re-
quirements may invalidate the CE conformity.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

    100 – 240V AC rating: 85 – 264V, 47 – 63 Hz, ≥ 130VA
    24V DC rating: 24V ±10%, ≥ 2.5A

 

GENERAL PRECAUTIONS

• Before you remove the unit from the base or mount it, 

turn off the power supply and input signal for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the installation base inside proper housing and 
ventilate it.

• Do not install the base where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within 0 to 55°C or 

32 to 131°F (0 to 50°C or 32 to 122°F for AC power) with 
relative humidity within 30 to 90% RH (30 to 85% RH 
for AC Power) in order to ensure adequate life span and 
operation.

• Be sure that the ventilation slits are not covered with ca-

bles, etc.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• When using M2 power, use a ferrite core close to the unit 

for power line. Using ferrite core is enough to eliminate 
noises, but turning the cable twice (1 round) as figure be-
low is recommended.

• Be sure to close the terminal cover for safety.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

COMPONENT IDENTIFICATION

 

REAR VIEW

Specifications

MOUNTING REQUIREMENTS

  unit: mm (inch)

460 (18.11)

4–M5 SCREW

50 (1.97)

Reviews: