CONNECTION DIAGRAM

1

2

+

2.4 kΩ

2.5 V

+

+

OUTPUT

5

6

+

INPUT

1

2

■ 

Open Collector or 

  Mechanical Contact

Input Connection Examples 

■ 

Voltage Pulse

1

2

+

8

7

POWER

CONNECTOR

POWER

 

WIRING INSTRUCTIONS

  • Applicable wire size

     

Solid:     0.2 to 2.5 mm

2

 (0.55 to 1.75 dia.)

     

Stranded:  0.2 to 2.5 mm

2

 (Tinning wire ends may 

     

 

 

  cause contact failure and therefore is not 

       

 recommended.)

     

 Ferruled:  0.2 to 1.5 mm

2

 (0.55 to 1.35 dia.)

  • Expose wire conductors by 8 mm (0.31”).

Expose 8 mm

• How to Connect Wires

Screwdriver

Wire

1) Insert a minus screwdriver into the wire entry opening, 

between the clamp and the housing, until its tip hits the 

bottom where it is firmly held.

Tension Clamp

Screwdriver

2) Insert a wire.  Push the screwdriver toward the direction 

indicated with the arrow in the figure below to widen the 

opening if necessary.

Wire Entry

Wire

3) Confirm that the wire tip hits the bottom and pull out the 

screwdriver in holding it in position.

  Confirm that the wire’s insulation tube is not caught in 

the clamp.

Summary of Contents for M6SPA

Page 1: ...ure the CE conform ity Install lightning surge protectors for those wires connect ed to remote locations POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V 10 approx 0 5W GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply and input signal for safety ENVIRON...

Page 2: ...N Rail B REMOVING THE UNIT A Pull down the DIN rail adaptor using a minus screwdriv er B Pull out the lower part of the unit C Remove the upper part from the DIN rail A DIN Rail Adaptor C B TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit EXTERNAL DIMENSIONS unit mm inch 94 3 70 5 9 23 DIN RAIL 35mm wide DIN RAIL HOOK Use a mi...

Page 3: ...ilure and therefore is not recommended Ferruled 0 2 to 1 5 mm2 0 55 to 1 35 dia Expose wire conductors by 8 mm 0 31 Expose 8 mm How to Connect Wires Screwdriver Wire 1 Insert a minus screwdriver into the wire entry opening between the clamp and the housing until its tip hits the bottom where it is firmly held Tension Clamp Screwdriver 2 Insert a wire Push the screwdriver toward the direction indic...

Page 4: ... CALIBRATE THE OUTPUT SIGNAL Use a signal source and measuring instruments of sufficient accuracy level Turn the power supply on and warm up for more than 10 minutes 1 ZERO Apply 0 input and adjust output to 0 For a bidirectional output e g 5 5 V DC apply an input signal corresponding to 0 V DC output Same pro cedure in 3 2 SPAN Apply 100 input and adjust output to 100 3 Check ZERO adjustment agai...