M2LPM

P.  / 6

EM-5054-A Rev.2

POTENTIOMETER TRANSMITTER

(field- and PC-configurable)

MODEL

M2LPM

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner (body + base socket) ...................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.
The  M2LPM  is  programmable  using  the  PC  configurator 
software.  For detailed information on the PC configuration, 
refer to the M2LPMCFG instruction manual.  The M2LPM-
CFG PC Configurator Software is downloadable at M-Sys-
tem’s web site: http://www.m-system.co.jp.

POINTS OF CAUTION

 POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  85 – 264V AC rating: 85 – 264V, 47 – 66 Hz, approx. 4 – 6VA

 GENERAL PRECAUTIONS

• Before you remove the unit from its base socket or mount 

it, turn off the power supply and input signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +55°C     

(23 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Be sure that the ventilation slits are not covered with ca-

bles, etc.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close  to  noise  sources  (relay  drive  cable,  high  frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying  complete  performance  described  in  the  data 
sheet.

COMPONENT IDENTIFICATION

INSTALLATION

Loosen the fixing screw at the front of the unit in order to 
separate the body from the base socket.

 DIN RAIL MOUNTING

Set the base socket so that 
its  DIN  rail  adaptor  is  at 
the  bottom.    Position  the 
upper hook at the rear side 
of  base  socket  on  the  DIN 
rail and push in the lower.  
When removing the socket, 
push  down  the  DIN  rail 
adaptor  utilizing  a  minus 
screwdriver and pull.

 WALL MOUNTING

Refer  to  “EXTERNAL  DI-
MENSIONS.”

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

Body

Base Socket

Connection

Diagram

Specifications

Fixing Screw

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

+

U

V

5

8

1

CONFIGURATOR

JACK

9

12

OUTPUT

13
14

POWER

+

3

2

1

POTENTIOMETER

max.

min.