background image

M2EXS

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-5137-A Rev.3  P. 4 / 4

WIRING INSTRUCTIONS

 

SCREW TERMINAL 

Torque: 0.8 N·m

 

SOLDERLESS TERMINAL

Refer to the drawing below for recommended ring tongue 
terminal size.  Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm

2

 (AWG 22 to 16)

Recommended manufacturer: Japan Solderless Terminal 
MFG.Co.Ltd, Nichifu Co.,ltd

6 (.24) max

3.3 (.13) max

mm (inch)

CHECKING

1) Terminal wiring:  Check that all cables are correctly con-

nected according to the connection diagram.

2) Check DIP switch setting.
3) Input signal and power input voltage:  Check wiring 

across M2EXS and self-synch as follows; terminal 1 – S1, 

terminal 2 – S2, terminal 4 – S3, terminal 10– R1, and 

terminal 11 – R2.

  Be sure that the connection for R1 and R2 of the self-

synch.  When the connection is reversed, the signal condi-

tioner output will be shifted by 180°. 

4) Output:  Check that the load resistance meets the de-

scribed specifications.

MAINTENANCE

Regular calibration procedure is explained below:

 

CALIBRATION

Warm up the unit for at least 10 minutes.  Apply 0%, 25%, 
50%, 75% and 100% input signal.  Check that the output 
signal for the respective input signal remains within accu-
racy described in the data sheet.  When the output is out 
of tolerance, recalibrate the unit as explained in the users 
manual of the M2ECFG configurator software.  Or follow 
the procedure shown below.

• 

INPUT FINE ADJUSTMENT

Set the input signal to 0%, and adjust the input to 0% by 
[06] Angle offset.

• 

OUTPUT FINE ADJUSTMENT

1) Set the simulated input to 0%, and adjust the output sig-

nal to 0% by [71] Output Zero fine adjust.

2) Set the simulated input to 100%, and adjust the output 

signal to 100% by [72] Output Span fine adjust.

3) Again set the simulated input to 0%, confirm the output 

signal.

4) If output signal is shifted, repeat the procedure from 1) to 

3).

IGHTNING SURGE PROTECTION

M-System offers a series of lightning surge protector for 
protection against induced lightning surges.  Please contact 
M-System to choose appropriate models.

Reviews: