background image

JPSM

EM-1689 Rev.5

P. 1 / 8

Body

Base Socket

Connection

Diagram Label

Front Cover

Specification

Label

BEFORE USE ....

Thank you for choosing M-System.  Before use, check the
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.

■ 

PACKAGE INCLUDES:

Signal conditioner (body + base socket) ..................... (1)
Ordering Information Sheet ....................................... (1)

■ 

MODEL NO.

Check that model No. described on specification label is
exactly what you ordered.

■ 

INSTRUCTION MANUAL

This manual describes necessary points of caution when you
use this product, including installation and connection, hard-
ware setting, and basic maintenance procedures.
When you need to change software settings, please refer to
the Operation Manual for Model PU-2x (EM-9255), Section
B.
This unit is factory adjusted and calibrated according to the
Ordering Information included in the product package.  If you
don't need to change the pre-adjusted setting, you can skip
the sections on hardware setting and calibration in this
manual and the Operation Manual for Model PU-2x.

POINTS OF CAUTION

■ 

POWER INPUT RATING & OPERATIONAL RANGE

• Check the power rating for the unit on the specification label.

85 – 132V AC rating: 85 – 132V, 47 – 66 Hz, approx. 3.3VA
12, 24, and 48V DC ratings: Rating 

±

10%, approx. 3.3W

110V DC rating: 85 – 150V DC, approx. 3.3W

■ 

UNPLUGGING THE UNIT

• Before you remove the unit from its base socket or mount it,
turn off the power supply and input signal for safety.

■ 

ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ventila-
tion.
• Do not install the unit where it is subjected to continuous
vibration.  Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +60

°

C (23

to 140

°

F) with relative humidity within 30 to 90% RH in order

to ensure adequate life span and operation.

■ 

WIRING

• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind the unit's cables together with cables where
high noise levels are present.  Do not install them in the same
duct.

■ 

AND ....

• The unit is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data sheet.

The shape of base socket may be different
for some models. 

INSTRUCTION  MANUAL

MODEL

JPSM

PULSE ADDER

(field-programmable)

Front Cover (open)

Input Monitor LED PL2

Input Monitor LED PL1

Modular Jack

Status Indicator

COMPONENT IDENTIFICATION

■ 

HOW TO OPEN THE FRONT COVER:

Position your finger on the hook at the top of front cover and
pull.

■ 

FRONT PANEL CONFIGURATION

INSTALLATION

Detach the yellow clamps located at the top and bottom of the
unit for separating the body from the base socket.

■ 

DIN RAIL MOUNTING

Set the base socket so that its
DIN rail adaptor is at the bot-
tom.  Position the upper hook
at the rear side of base socket
on the DIN rail and push in the
lower.  When removing the
socket, push down the DIN rail
adaptor utilizing a minus
screwdriver and pull.

■ 

WALL MOUNTING

Refer to the drawings in the
next page.

Clamp

(top & bottom)

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

Shape and size of the base socket 
are slightly different with various 
socket types.

Summary of Contents for JPSM

Page 1: ...e present in the air install the unit inside proper housing with sufficient ventila tion Do not install the unit where it is subjected to continuous vibration Do not subject the unit to physical impact Environmental temperature must be within 5 to 60 C 23 to140 F withrelativehumiditywithin30to90 RHinorder to ensure adequate life span and operation WIRING Do not install cables power supply input an...

Page 2: ... 4 2 WIRE PICK UP DC SUPPLY 100Ω 5 6 2 WIRE PICK UP DC SUPPLY Voltage Pulse Open Collector Output Connection Examples 1 2 Voltage Pulse 1 2 Power Photo MOSFET Relay AC Powered 1 2 LOAD Relay or Counter Coil Varistor or Spark Quenching Circuit DC Powered 1 2 LOAD Relay or Counter Coil Spark Quenching Diode OUTPUT 1 2 U V POWER 7 8 INPUT 1 3 4 INPUT 2 5 6 PU 2 MODULAR JACK RS 422 Line Driver Pulse 2...

Page 3: ...of number of output pulses divided by number of input pulses are determined by two parameters input span frequency and output span frequency Although there are also input zero frequency and output zero frequency they are fixed to zero 0 Hz These span frequencies are only used to determine the rate therefore they do not limit actual input output frequencies For example ifyousettheinputspanfrequency...

Page 4: ...r to the tables below for the max frequency which can pass through the filter Not Used Sensitivity Adj VH Sensitivity Adj VL Not Used Sensor Excitation Adj Input Monitor LED PL1 Input Monitor LED PL2 Set each switch according to the table below SW1 front cover open Set each switch according to the table below O N 2 1 3 4 5 6 7 8 O N 2 1 3 4 5 6 7 8 SW2 STATUS INDICATOR LED The CPU status is indica...

Page 5: ...he negative probe of voltmeter to the terminal 4 of base socket See the figure to the right 2 If you need a noise filter turn on the SW1 5 2 5 or SW1 6 2 6 3 Connect the positive probe to the test hole No 2 and turn the VH potentiometer until the meter shows desired value 4 Connect the positive probe to the test hole No 3 and turn the VL potentiometer until the meter shows desired value 5 Apply in...

Page 6: ...ts the first pulse sinking after its rising since the power is turned on For voltage pulse the first count is made when waveform shifts from High to Low status while for a dry contact it is made when the wave shifts from OFF to ON Turn the front DIP SW SW2 4 or 1 4 ON or OFF respectively so that the Input Monitor LED PL1 or PL2 is turned ON The transmitter counts the first pulse rising after its s...

Page 7: ... DISPLAY CONTENTS Model indication 01 00 JPRD Maintenance switch 01 01 maintenance sw Switching to PROGRAM mode which allows parameter change Tag No 01 02 user s TAG entry User s Tag name entry and monitor Input frequency monitor 01 05 measured input Input 1 frequency in Input frequency monitor 01 06 measured freq Input 1 frequency in in Hz Input counter value 01 07 input counts Total number of in...

Page 8: ...in materials and workmanship during the 36 month period following the date that such productwasoriginallypurchasedifsuchproducthasbeenusedundernormaloperatingconditionsandproperlymaintained M System ssoleliability andpurchaser sexclusiveremedies under this warranty are at M System s option the repair replacement or refund of the purchase price of any M System product which is defective under the t...

Reviews: