190
A
D
B
Fig. 9.1
CONNECTING THE FEEDER CABLE
To connect the feeder cable to the cook-
er it is necessary to:
– Remove the two screws that hold
shield
A
behind the cooker. (Fig. 9.1).
– Open completely the cable clamp
D
.
– Fitted with a 5-pole terminal block,
position the U bolts onto terminal
block ‘
B
’ (fig. 9.1) according to the
diagrams in figs. 9.2 - 9.3.
– Feed the supply cable through the cable
clamp “
D
”. The supply cable must be of
a suitable size for the current require-
ments of the appliance; see the section
“Feeder cable section”
– Connect the phase and earth cables
to terminal
B
according figure 9.1.
– Pull the feeder cable and block it with
the cable clamp
D
– Re-mount shield
A
.
N.B. Earth cable must be 3 cm longer
than neutral and live cables.
FEEDEER CABLE SECTION
“TYPE H05RR-F”
230 V
3 x 6 mm
2
(**)
230 V3
4 x 4 mm
2
(**)
400 V 3N
5 x 2,5 mm
2
(**)
400 V 2N
4 x 4 mm
2
(**)
(**) – Connection with wall box connection.
– Contemporaneity factor applied
PE
1 2 3 4 5
N (L
2
)
L
1
230 V
230 V3
PE
1 2 3 4 5
PE
1 2 3 4 5
PE
1 2 3 4 5
400 V 2N
400 V 3N
L
1
L
2
L
3
N
L
1
L
2
L
3
N
L
1
L
2
Fig. 9.2