ANTINOISE ELECTRICAL CONNECTION

• Lightning surge protection 

In order to protect the unit from lightning surges enter-
ing through cables, use of appropriate lightning surge 
protectors are recommended.  Installing a noise filter 
enables protection from various electrical stresses.

• Ground the earth screw.  If the unit is installed in the 

environment without earthing, it may cause a malfunc-
tion or failure.

 

DESIGNING  JOINT AND YOKE 

• Operate this unit within specified voltage and frequency.  

The rated output torque is 70 N

·

m.  Do not operate this 

unit within the condition that the output stem is locked. 
(The valve stem is locked or more than 120 N

·

m torque 

is necessary.)  Design the connected stem so that it is not 
sheared.  Observe enough strength when designing the 
yoke so that there is no bending and distortion.

• Prevent from heat conduction and radiation when con-

necting surface is high temperature or its radiated heat 
is high. If the temperature of the unit rises by a heat con-
ducted or radiated from external, it may cause a failure.

 

ENVIRONMENT

• The unit does not endure all vibration at installation site.  

Even if that is low vibration, the unit cannot be guaran-
teed over a long period.  Please use after evaluation with 
customer’s installation environment. (Particularly avoid 
using at the place where there is water hammer, steam 
hammer or cavitation on the valve side.)

• The actuator must be installed in a place where mainte-

nance and inspection can be conducted.  Leave spaces of 
at least 20 cm (7.9 in.) for maintenance and inspection 
above the unit and around its terminal cover.

• DO NOT use in hazardous atmosphere such like explosive 

gases, corrosive gases, corrosive liquids or salt pollution.

 

OPERATING CONDITION

• Depending on operating condition, the internal tempera-

ture may rise extremely high.

• Operating continuously under such conditions results in 

short life span or damage of the product and may impair 
expected performance.

• Operate with an enough margin such as shortening the 

operational duty time ratio (duty ratio of <50% or less 
than 13 strokes per minute).

Summary of Contents for EAR70

Page 1: ...hock or electric leakage due to dew condensation A fuse is installed on the top side of the control PWB in side the unit for safety It is 250 V 2 A slow blow type A spare fuse is secured on the base p...

Page 2: ...necting surface is high temperature or its radiated heat is high If the temperature of the unit rises by a heat con ducted or radiated from external it may cause a failure ENVIRONMENT The unit does n...

Page 3: ...12 sq Manual Operation Stem 8 sq Control PWB Terminal BOX Cover Screw Earth Symbol Earth Screw 2 G3 4 Conduit Port 2 G1 2 Conduit Port Motor Capacitor Plate Specifications POWER VOLTAGE INPUT OUTPUT F...

Page 4: ...operation stem cannot be operated Shape of the manual operation stem is 8 mm square Use an adequate wrench Moving the output stem to the direction of full open turn the manual operation stem to the r...

Page 5: ...atically judges the abnormally low input if the input signal is suddenly fallen to the lower of the set value from 20 mA position or middle position SELECTABLE BY ORDERING INFROMATION POSITION OF SW1...

Page 6: ...T STEM Viewing from indicator OUTPUT SW 4 mA DC Open 90 Turn Counter Clockwise OPEN O 4 mA DC 1 2 3 4 ON 20 mA DC Shut 0 Trun Clockwise SHUT S 20 mA DC VOLTAGE INPUT CCW INPUT POSITION OF OUTPUT STEM...

Page 7: ...of full open position Operation direction of output stem differs according to the rotation direction of each adjuster as following 20mA DC input full open 90 SPAN approx 5 approx 4 SPAN ZERO ZERO max...

Page 8: ...stallation during operation tactile No deterioration and changes of the packing and O ring between the mechanism and the cover and on the inner surface of the lid of the BOX visual NO NECESSARY CHECKI...

Reviews: