TABLE FOR THE CHOICE OF THE INJECTORS -
Cat:
II
2L 3B/P
NL
TABLE FOR THE CHOICE OF THE INJECTORS -
Cat:
II
2E+ 3+
FR
BE
A
IR
VENT
NECESSARy
FOR
GAS
COmBUSTION
= (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Triple ring (TR)
7,00
G30/G31
30/30 mbar
G25
25 mbar
BURNERS
Nominal
Power
[Hs - kW]
Reduced
Power
[Hs - kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,30
50
80
Semi-rapid (SR)
1,75
0,45
66
102
Rapid (R)
3,00
0,75
87
132
Triple ring (TR)
3,50
1,50
93
140
G30/G31
28-30/37 mbar
G20/G25
20/25 mbar
BURNERS
Nominal
Power
[Hs - kW]
Reduced
Power
[Hs - kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,30
50
77
Semi-rapid (SR)
1,75
0,45
66
101
Rapid (R)
3,00
0,75
87
129
Triple ring (TR)
3,50
1,50
93
135
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be
fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
Summary of Contents for B-MFCD 95 Series
Page 29: ...29 S F C T Afb 7 1 Afb 7 2 A B S T Afb 7 3 Afb 7 4 Afb 7 5...
Page 50: ...50...
Page 78: ...78 A B S T Abb 7 3 Abb 7 4 Abb 7 5 S F C T Abb 7 1 Abb 7 2...
Page 99: ...99...
Page 126: ...126 S F C T Fig 7 1 Fig 7 2 A B S T Fig 7 3 Fig 7 4 Fig 7 5...
Page 147: ...147...
Page 174: ...174 A B S T Fig 7 3 Fig 7 4 Fig 7 5 S F C T Fig 7 1 Fig 7 2...
Page 195: ...195...