background image

A-34

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7459  Rev.3  P. 2 / 5

INSTALLATION

The A-34 allows the adapted transmitter/indicator to be mounted on a DIN rail.
Use the spacer screws to attach the 26-UNIT (option /266) or 27-UNIT (option /276) transmitter to the A-34 (spacer torque 
0.8 N·m, screw torque 0.8 N·m).
The spacer screws may be loosened when loosening the mounting screws on the 6DV indicator connected to the 26-UNIT or 
27-UNIT transmitter via the spacer.  Confirm that the spacer screws are tightened before tightening the 6DV indicator.  If it 
is difficult to loosen only the mounting screws because of both screws turning together, detach them together first and then 
loosen the mounting screws only by holding the spacer screw from behind.
Use the wire included in the package to connect between the 26-UNIT or 27-UNIT transmitter and the 6DV indicator.  For 
more information, refer to the connection diagram for the 6DV.

 

HOW TO ATTACH THE ADAPTER

Attach the transmitter/indicator to the adaptor with screws/spacer included in the product package.

• A-34

Screw

DIN Rail Mounting Adapter

Nut

Spring

Washer

• A-34/276

Screw

Spacer

DIN Rail Mounting Adapter

Nut
Spring

Washer

• A-34/6DV

Screw

Spacer

DIN Rail Mounting Adapter

Nut
Spring

Washer

 

HOW TO MOUNT THE ADAPTER TO THE DIN RAIL

Set the DIN Rail Mounting Adapter so that its DIN rail 
adaptor is at the bottom.  Hang the upper hook at the rear 
side of the module on the DIN rail and push in the lower.  
When removing the product, push down the DIN rail adap-
tor utilizing a minus screwdriver and pull.

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor