– 12 –
n
PANEL MOUNTING
(1) Insert the 73VR3100 from the front side of the panel.
(2) Remote the sheets covering the mounting bracket holes. Fix two mounting brackets
either on the sides or on the top and bottom of the unit. Tighten screws.
CAUTION !
Adequate tightening torque for the screws used to mount the unit onto the panel is be-
tween 0.8 and 1.2 N·m. If an excessive force is applied, the unit’s enclosure may be
destroyed, or the panel may be distorted, which would cause a compromise in the unit’s
protection against water or liquid ingress.
Bracket
Panel