FRONT PANEL CONFIGURATION

 ALARM OUTPUT CODE 2: 2 points

 ALARM OUTPUT CODE 4: 4 points

• Bar Color Patterns

Pattern 1 (Bar LED color code C1)

orange

orange

green

orange

Input < L

L < Input < H

H < Input

green

red

H

L

Pattern 2 (Bar LED color code C2)

orange

green

green

red

red

red

H

L

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

100 SET

H

S

Z

L

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

H Setpoint Adj. & Trip Indicator (red)
Span Adj. (amber)
Power Saving Mode Indicator (amber)
Zero Adj. (amber)
L Setpoint Adj. & Trip Indicator (green)

UP Button

Mode Selector

DOWN Button

H Setpoint

L Setpoint

PV Indicator

M

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

100

SET

L

Z

S

90

80

70

60

50

40

30

20

10

0

H

M

• Vertical Mounting

• Horizontal Mounting

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

100 SET

H

S

Z

L

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

HH Setpoint Adj. & Trip Indicator (red)
H Setpoint Adj. & Trip Indicator (red)
Span Adj. (amber)
Power Saving Mode Indicator (amber)
Zero Adj. (amber)
L Setpoint Adj. & Trip Indicator (green)
LL Setpoint Adj. & Trip Indicator (green)

UP Button

Mode Selector

DOWN Button

HH Setpoint

H Setpoint

L Setpoint

LL Setpoint

PV Indicator

HH

LL

M

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

100

SET

LL

L

Z

S

90

80

70

60

50

40

30

20

10

0

H

HH

M

• Vertical Mounting

• Horizontal Mounting

Summary of Contents for 48NAV

Page 1: ...the operator to turn off the power in put immediately install a switch or a circuit breaker ac cording to the relevant requirements in IEC 60947 2 and properly indicate it POWER INPUT RATING OPERATION...

Page 2: ...e at the minimum of 3 cm above and below the units for heat dissipation Note 2 No bezel is needed when the panel is cut according to the above drawings Panel thickness 1 6 8 0 mm Panel thickness 1 6 8...

Page 3: ...mm Slide the top and bottom parts of the bezel into the back of the front cover as shown below Bezel When multiple units are to be clustered side by side insert one bezel between two units as shown be...

Page 4: ...13 14 15 16 16 M3 SCREW TERMINALS Rounded corners for the option D 2 M3 SCREWS 144 5 67 137 5 5 41 4 1 16 36 1 42 OPTION D BEZEL 3 1 Space required when replacing the scale plate 2 Used for the exist...

Page 5: ...ay Protection AC Powered 7 8 9 8 9 10 HHa 7 Hc HHc HHb Ha HH OUTPUT H OUTPUT LL OUTPUT L OUTPUT ARARM OUTPUT CODE 2 2 points ARARM OUTPUT CODE 4 4 points U V La Lb Lc Hc Ha Hb H OUTPUT L OUTPUT POWER...

Page 6: ...or amber Zero Adj amber L Setpoint Adj Trip Indicator green UP Button Mode Selector DOWN Button H Setpoint L Setpoint PV Indicator M 50 40 30 20 10 0 10 20 30 40 50 m3 h 100 SET L Z S 90 80 70 60 50 4...

Page 7: ...LED OFF LED Blinking Mode Selector 1 S SET S M Span Adjustment Complete SPAN ADJUSTMENT Apply 100 input signal before adjustment ALARM SETTING Proceed after the zero span adjustments 1 Keep pressing...

Page 8: ...ter it has been used to choose a indicator LED programming mode During this period pressing the M button briefly is enough to choose another indicator After 1 minute it turns to deac tivated state CAL...

Reviews: